SEGMENsensor builds clamp-on ultrasonic flow meters under your brand. The compact U12 one-piece meter covers DN15–DN65 pipes with 4–20 mA and RS485 Modbus outputs, and ships with your faceplate and nameplate, an English display menu, a factory calibration report and neutral export packaging. For instrument brands, distributors and system integrators that sell under their own name.
SEGMENsensor supplies clamp-on ultrasonic flow meters as private-label (white-label) products: the meter is built and calibrated in our Shenzhen factory and delivered with your brand on the faceplate and nameplate, an English menu and neutral packaging, so you sell it as your own model.
Looking for a clamp-on ultrasonic flow meter to sell under your own brand? Here is how SEGMENsensor private-label supply works. The usual base model is the U12 one-piece meter. It clamps straight onto DN15 to DN65 pipes, with no pipe cutting, and it is CE and UKCA marked. From the datasheet: velocity from 0.03 to 10 m/s, and ±2% accuracy, or ±1% after calibration. Choose any two of 4–20 mA, RS485 Modbus, pulse or relay. Power is 10–24 V DC, and the housing is IP65. On a private-label meter, we print your logo, colours and model code on the faceplate, and your data on the nameplate. The display menu is in English, with other languages on request for your market. Every private-label meter can ship with a factory calibration report, with three-point calibration available. Neutral export cartons carry no maker marks, and we photograph each packed batch for your approval before it ships. Each meter is tested on the water flow test line before it is packed. A project runs in six steps: your specification, an artwork proof, branded samples, order confirmation, production and calibration, and finally packed-batch approval. Branded qualification samples of 1–5 pieces ship in 5–7 days. Production lead time and order quantity are confirmed with the quotation. Send your specification and brand files through segmensensor.com, and our engineers will reply within 24 hours.
A private-label flow meter is made by one manufacturer and sold under another company's brand. The buyer supplies the logo, model code and label artwork; the manufacturer builds, calibrates and packs the meter to that specification, with no manufacturer name on the product or carton. Instrument brands and distributors use private label to add a clamp-on ultrasonic flow meter to their range without developing the electronics, transducers and firmware themselves.
The faceplate, nameplate, display menu language, packaging, calibration paperwork and output combination can all be set to your brand. The table shows what is standard and what is confirmed per project.
| Item | What we supply | Status |
|---|---|---|
| Faceplate | Front label printed with your logo, colours and model code | Standard for private label |
| Nameplate | Rating label with your brand, model and the data you specify | Standard for private label |
| Display menu | English menu; no Chinese text on the display | Standard; other menu languages on request for your market |
| Packaging | Neutral export carton suitable for international courier, without SEGMENsensor marks or Chinese labels | Standard for private label |
| Packing approval | Photo of each packed batch (converter and sensors together) sent before dispatch | Available to every private-label customer |
| Calibration | Factory calibration report per unit; three-point calibration available | Available to every private-label customer |
| Outputs | Any two of 4–20 mA, RS485 Modbus, OCT pulse and one relay (U12) | Chosen at order |
| Wireless | LoRa or 4G communication (U12) | Customised per project |
| Cable | 2 m standard, up to 5 m (U12) | Chosen at order |
| Energy metering | E type heat / cooling energy meter with PT1000 temperature sensors | Chosen at order |
We do not disclose customer names, brands or volumes, and private-label products carry no reference to SEGMENsensor.
Any model in the range can be supplied under your brand. Small-pipe buyers usually start with the U12 or U13 one-piece meters; the U10S and U20 cover larger pipes and portable surveys.
| Parameter | U12 one-piece | U13 one-piece | U10S wall-mount | U20 handheld |
|---|---|---|---|---|
| Pipe size | DN15–DN65 | DN10–DN40 (OD 12–52 mm) | 15–1200 mm | 25–1200 mm (1"–48") |
| Velocity | 0.03–10 m/s | 0.15–10 m/s | ±0.03 to ±5 m/s | ±0.01 to ±12 m/s |
| Accuracy | ±2% (±1% after calibration) | <3% FS (<1.5% FS after calibration) | ±1% | ±1% |
| Outputs | Two of 4–20 mA, RS485 Modbus, OCT, relay | 4–20 mA, RS485 Modbus; optional OCT or relay | Two of 4–20 mA, pulse, RS232 / RS485 Modbus | Two of 4–20 mA, RS485 Modbus, OCT, relay |
| Supply | 10–24 V DC | 20–28 V DC | 10–36 V DC; optional 90–245 V AC | 3000 mAh battery, about 16 h |
| Protection | IP65 | See datasheet | Transmitter IP65, sensors IP68 | Sensors IP68 |
| Certifications | CE, UKCA | CE, UKCA | CE, UKCA | CE, UKCA |
The U12 clamps directly onto DN15–DN65 pipes with the transducers built into the housing, so there is no separate converter to mount and no pipe cutting. The front faceplate carries the brand, model code and keypad graphics — this is the area replaced with your artwork. Cable connections are at the top of the housing, and the meter is CE and UKCA marked.
| Pipe size | DN15 | DN20 | DN25 | DN32 | DN40 | DN50 | DN65 |
|---|---|---|---|---|---|---|---|
| Upper flow limit (L/min) | 60 | 100 | 200 | 300 | 400 | 600 | 1000 |
Values from the SEGMENsensor U10–U20 datasheets. Minimum measurable pipe inner diameter for the U12 is 12 mm. Full specifications: clamp-on ultrasonic flow meters and portable clamp-on flow meter.
It runs in six steps: specification, artwork proof, qualification samples, approval, production and packed-batch approval before dispatch.
Typical buyers, evaluated per project.
Answers for instrument brands and distributors planning a private-label range.
Send the model, pipe sizes, outputs and your brand files — our engineers reply within 24 hours. Branded qualification samples of 1–5 pcs ship in 5–7 days.
Tell us your specification — our engineers reply within 24 hours.
Standard SEGMENsensor models and OEM supply terms.