U11 High-Accuracy Clamp-On Ultrasonic Flow Meter
The SEGMENsensor U11 is a high-accuracy, wall-mount transit-time flow meter that clamps onto full pipes of a single, sound-conducting liquid. It reads ±0.5% with 0.1% repeatability over ±0.01 to ±12 m/s, runs on 90–245 V AC or 10–36 V DC, and ships from our factory within 2 weeks of payment.
- ±0.5%accuracy, 0.1% repeatability
- ±0.01–12 m/sflow velocity range
- 2 of 5outputs included: 4–20 mA, pulse, relay, RS232, RS485
- AC or DC90–245 V AC or 10–36 V DC
- Ships within 2 weeksMade to order and shipped from our factory within 2 weeks of payment.
- Customs documents suppliedWe send the commercial invoice and packing list for your import clearance.
- Calibration reportEvery meter is calibrated before it leaves the factory and ships with its report.
- Engineers by emailReply within one working day, Mon–Fri 09:00–18:00 China time.
From order to your door
- TodayConfigure and pay
Card, PayPal or bank transfer. UPS shipping is added at checkout; import duty and tax are not included.
- Within 2 weeksBuilt and calibrated
Your meter is made to order, calibrated before it leaves the factory and packed in its own box.
- 3–5 working daysUPS
Door to door from our factory to your company address, usually 3–5 working days.
- DeliveredYou clear customs
You pay import duty and tax in your country, usually through UPS or your customs broker. We supply the commercial invoice and packing list.

What's in the box
Standard configuration, included in the unit price:
- U11 transmitter with back frame for wall mounting
- One pair of transducers with cable — the configuration you choose
- Two 1.3 m pipe straps (fit pipes up to DN300) and coupling compound
- User manual
- Factory calibration report
- Any options you add, such as the PT1000 temperature sensors
Which transducer do I need?
Choose A2 for liquid up to +80 °C, H1A up to +130 °C and H2A up to +180 °C; each pair covers DN25–DN1200. Every configuration is the U11 transmitter with one pair of transducers; options and extra cable are added on top. For small pipes (DN15–DN40) or pipes above DN1200, ask our engineers.
- U11 transmitter with back frame for wall mounting
- One pair of transducers with cable
- Two 1.3 m pipe straps (fit pipes up to DN300) and coupling compound
- User manual
- Factory calibration report
| Your pipe and liquid | Part number | Transducer | Cable | Unit price (USD) | |
|---|---|---|---|---|---|
| DN25–DN1200, liquid up to +80 °C | U11-A2 | Standard A2 clamp-on transducers. One pair covers DN25–DN1200; for pipes above DN300 you add extra straps. | 9 m | US$1,590 | Select |
| DN25–DN1200, +80 to +130 °C | U11-H1A | High-temperature H1A transducers for hot water and condensate lines. For pipes above DN300 you add extra straps. | 9 m | US$1,690 | Select |
| DN25–DN1200, +130 to +180 °C | U11-H2A | H2A transducers for liquids up to +180 °C. For pipes above DN300 you add extra straps. | 9 m | US$1,890 | Select |
| Clamp-on not suitable | U11-I1 | Insertion transducers, −40 to +130 °C. Our engineers confirm the installation for your pipe before the meter ships. | 9 m | US$1,690 | Select |
Options — added to the unit price
| Code | Option | Price (USD) |
|---|---|---|
DC | 10–36 V DC power supply | No extra charge |
E | Energy (BTU) meter, clamp-on PT1000 | +US$179 |
HT | HART (4-wire), replaces RS232 | Price on request |
I1H | High-temperature insertion transducers, up to +180 °C | Price on request |
B1 / B1H | Small-pipe clamp-on transducers, DN15–DN40 | Price on request |
Cable H2A | Extra cable for H2A transducers | Price on request |
Extra cable and pipe straps
| Code | Item | Price (USD) |
|---|---|---|
CABLE-80 | Extra transducer cable, up to +80 °C | +US$5 |
CABLE-130 | Extra transducer cable, up to +130 °C | +US$9 |
STRAP2 | Extra or spare 1.3 m pipe straps | +US$11.50 |
- Transducer cable: 9 m standard, custom up to 274 m.
- Insertion transducers: tell us the pipe material so the mounting base matches it. Standard pressure rating 1.6 MPa.
How do I install the U11?
The U11 installs from outside the pipe in four steps, with no cutting and no shutdown. The diagrams come from the U11 user manual.
- Mount the back frame
Fit the back frame to the transmitter, vertical or horizontal, then fix it to the wall with expansion screws in Ø6 mm holes at 228 × 178 mm.
- Choose a straight, full pipe
After a 90° bend, leave at least 10 pipe diameters upstream and 5 downstream. Valves and pumps need longer runs — see the manual.
- Strap on the transducers
Mount them at 3 or 9 o'clock on horizontal pipes, never at the top or bottom. V method is standard; Z method gives a stronger signal on large pipes.
- Enter the pipe data
Key in the pipe size, material and liquid. The meter shows the transducer spacing; set it and read the flow.


U11 dimensions
| Transmitter | 254 × 230 × 64 mm (W × H × D) |
|---|---|
| Clamp-on transducer (A2, H1A, H2A) | 68 × 34 × 34 mm |
| Insertion transducer (I1) | Length 260.5 mm, G1" thread |
| Wall mounting | Back frame, Ø6 mm holes at 228 × 178 mm |
U11 specifications
| Pipe size | 15–5000 mm depending on transducer; DN25–DN1200 with one pair of A2, H1A or H2A clamp-on transducers (the configurations on this page) |
|---|---|
| Flow velocity | ±0.01 to ±12 m/s |
| Accuracy | ±0.5% |
| Repeatability | 0.1% |
| Liquid | Single, sound-conducting liquid in a full pipe |
| Signal processing | FPGA chip with TGA algorithm; tolerates intermittent bubbles or particles for up to 5 s; samples up to 300 times per second |
| Outputs | Choose 2 of 5: 4–20 mA (max. load 750 Ω); pulse / OCT 0–9999 Hz, adjustable min. and max. frequency; relay SPST, max. 1 Hz (0.4 A @ 125 V AC or 2 A @ 30 V DC); RS232 Modbus; RS485 Modbus |
| Communication option | HART (replaces RS232) — price on request |
| Power supply | 90–245 V AC, 48–63 Hz, or 10–36 V DC |
| Protection | Transducers IP68 |
| Transducer temperature | A2 −40 to +80 °C; H1A −40 to +130 °C; H2A −40 to +180 °C; I1 −40 to +130 °C |
| Data logging | Fcard, expandable to 32 GB |
| Transducer cable | 9 m standard; custom up to 274 m |
| Certifications | CE, UKCA — EMC tested to EN IEC 61000-6-2 and EN IEC 61000-6-4 (certificate copies on request) |
Spare parts for the U11
Order replacement transducers, temperature sensors and installation parts for the U11 on their own. Prices are per item, excluding shipping and import duties.
| Code | Part | Price (USD) | Qty |
|---|---|---|---|
SP-A2 | Pair of A2 clamp-on transducers Standard item: One pair comes with the A2 configuration. | US$289 | |
SP-H1A | Pair of H1A clamp-on transducers Standard item: One pair comes with the H1A configuration. | US$479 | |
SP-H2A | Pair of H2A clamp-on transducers Standard item: One pair comes with the H2A configuration. | US$899 | |
SP-I1 | Pair of I1 insertion transducers Standard item: One pair comes with the I1 configuration. | US$479 | |
SP-I1H | Pair of I1H high-temperature insertion transducers Standard item: One pair comes with the I1H configuration. | US$2,049 | |
SP-PT1000 | Pair of clamp-on PT1000 temperature sensors | US$139 | |
SP-ENC | Transmitter enclosure | US$389 | |
SP-MNT | Mounting kit Standard item: Supplied with every meter. | US$29 | |
SP-ST | Pair of stainless-steel pipe straps, 1.3 m Standard item: 2 straps (1 pair) come with every meter. | US$11.50 | |
SP-CPL | Coupling compound, one tube Standard item: Coupling compound comes with every meter. | US$11.50 |
Shipping, duties and delivery
- We ship from our factory in China within 2 weeks of payment. Every meter ships in its own box.
- UPS delivers door to door, usually in 3–5 working days after dispatch. The UPS shipping cost is shown at checkout and paid with your order.
- Import duty, VAT or GST and any customs fees are not included in the price or the checkout total. You pay them as the importer in your country, and the rates differ by country.
- We help with customs clearance: the commercial invoice and packing list go with the shipment and by email, and our engineers answer customs questions about the product.
- Prices on this page are per unit, excluding shipping and import duties, for 1–9 units. For 10 units or more, email info@segmensensor.com and we will recalculate the price for your quantity.
Frequently asked questions
Will the U11 work on my pipe?
The U11 measures full pipes carrying a single, sound-conducting liquid such as water or chilled water. The clamp-on configurations on this page cover DN25–DN1200 at up to +80 °C (A2), +130 °C (H1A) or +180 °C (H2A). If you are unsure, send us the pipe size, material, liquid and temperature and our engineers will reply by email within one working day.
How is the U11 different from the U10?
The U11 is the high-accuracy model: ±0.5% and 0.1% repeatability against ±1% and 0.2% for the U10, a wider velocity range of ±0.01 to ±12 m/s, AC or DC power, and an FPGA-based signal processor that rides through bubbles or particles for up to 5 s. Choose the U10 when ±1% is enough for the job.
What does the price include?
The price is per unit and includes the transmitter with its back frame, one pair of transducers with cable, two 1.3 m pipe straps for pipes up to DN300, coupling compound, the user manual and a factory calibration report. UPS shipping is added at checkout. Import duty and tax are not included; you pay them in your country on import.
My pipe is larger than DN300. How many straps do I need?
The two pipe straps in the box are 1.3 m long and fit pipes up to DN300. Each transducer is held by one strap loop around the pipe, and the loop needs about 3.14 × the pipe outside diameter, plus a little to tighten. Extra straps are the same 1.3 m straps and join onto the standard ones, so every extra pair adds 1.3 m to both loops. Work out what your pipe needs and choose the number of extra pairs in step 1 of the configurator; they are charged per pair, and the price is shown before you pay. If your pipe is DN300 or smaller and you want spares, add spare pairs of 1.3 m straps under Options in step 3.
Can the U11 measure heating or cooling energy?
Yes. Add the energy (BTU) option in step 3: it fits an RTD module and a pair of clamp-on PT1000 temperature sensors with 9 m cable, and the meter then calculates heating or cooling energy from flow and the supply and return temperatures.
Which outputs can I have?
Two of five outputs are wired at the factory: 4–20 mA, pulse / OCT, relay, RS232 Modbus or RS485 Modbus. You choose the two in the configurator, at no extra cost. HART is available on request and replaces RS232; email us for the price.
Do I pay import duty when the meter arrives?
Yes. Import duty, VAT or GST and any customs fees are paid by you as the importer, and the rates depend on your country. UPS or your customs broker will ask for payment before or at delivery. We send the commercial invoice and packing list with the shipment and by email, and help with customs questions about the product.
When will my order arrive?
We ship from our factory within 2 weeks of payment. UPS then usually takes 3–5 working days to deliver. The configurator shows an estimated delivery date before you pay.
Can I order 10 or more units?
Yes. For 10 units or more, email info@segmensensor.com with the part number and quantity. Our engineers recalculate the price for your quantity and reply by email.
Distributor or reseller? See what it takes to become a SEGMENsensor distributor →