U11 · wall-mount · high accuracy

U11 High-Accuracy Clamp-On Ultrasonic Flow Meter

The SEGMENsensor U11 is a high-accuracy, wall-mount transit-time flow meter that clamps onto full pipes of a single, sound-conducting liquid. It reads ±0.5% with 0.1% repeatability over ±0.01 to ±12 m/s, runs on 90–245 V AC or 10–36 V DC, and ships from our factory within 2 weeks of payment.

  • ±0.5%accuracy, 0.1% repeatability
  • ±0.01–12 m/sflow velocity range
  • 2 of 5outputs included: 4–20 mA, pulse, relay, RS232, RS485
  • AC or DC90–245 V AC or 10–36 V DC
Price for selected configurationFrom US$1,590per unit · excl. shipping and import duties · same price for 1–9 units
  • Ships within 2 weeksMade to order and shipped from our factory within 2 weeks of payment.
  • Customs documents suppliedWe send the commercial invoice and packing list for your import clearance.
  • Calibration reportEvery meter is calibrated before it leaves the factory and ships with its report.
  • Engineers by emailReply within one working day, Mon–Fri 09:00–18:00 China time.

SEGMENsensor Engineering Team · Last updated: 1 November 2026

From order to your door

  1. TodayConfigure and pay

    Card, Apple Pay or Google Pay. UPS shipping is added at checkout; import duty and tax are not included.

  2. Within 2 weeksBuilt and calibrated

    Your meter is made to order, calibrated before it leaves the factory and packed in its own box.

  3. 3–5 working daysUPS

    Door to door from our factory to your company address, usually 3–5 working days.

  4. DeliveredYou clear customs

    You pay import duty and tax in your country, usually through UPS or your customs broker. We supply the commercial invoice and packing list.

Everything in the U11 box laid out: transmitter, transducers with cable, pipe straps, couplant, mounting hardware and manual

What's in the box

Standard configuration, included in the unit price:

  • U11 transmitter with back frame for wall mounting
  • One pair of transducers with cable — the configuration you choose
  • Two 1.3 m pipe straps (fit pipes up to DN300) and coupling compound
  • User manual
  • Factory calibration report
  • Any options you add, such as the PT1000 temperature sensors

Which transducer do I need?

Choose A2 for liquid up to +80 °C, H1A up to +130 °C and H2A up to +180 °C; each pair covers DN25–DN1200. Every configuration is the U11 transmitter with one pair of transducers; options and extra cable are added on top. For small pipes (DN15–DN40) or pipes above DN1200, ask our engineers.

Every standard configuration includes, in the unit price:
  • U11 transmitter with back frame for wall mounting
  • One pair of transducers with cable
  • Two 1.3 m pipe straps (fit pipes up to DN300) and coupling compound
  • User manual
  • Factory calibration report
Your pipe and liquidPart numberTransducerCableUnit price (USD)
DN25–DN1200, liquid up to +80 °CU11-A2Standard A2 clamp-on transducers. One pair covers DN25–DN1200; for pipes above DN300 you add extra straps.9 mUS$1,590Select
DN25–DN1200, +80 to +130 °CU11-H1AHigh-temperature H1A transducers for hot water and condensate lines. For pipes above DN300 you add extra straps.9 mUS$1,690Select
DN25–DN1200, +130 to +180 °CU11-H2AH2A transducers for liquids up to +180 °C. For pipes above DN300 you add extra straps.9 mUS$1,890Select
Clamp-on not suitableU11-I1Insertion transducers, −40 to +130 °C. Our engineers confirm the installation for your pipe before the meter ships.9 mUS$1,690Select

Options — added to the unit price

CodeOptionPrice (USD)
DC10–36 V DC power supply
Instead of the 90–245 V AC supply. Tick this if your site has DC power only.
No extra charge
EEnergy (BTU) meter, clamp-on PT1000
RTD module plus a pair of clamp-on PT1000 temperature sensors, 9 m cable.
+US$179
HTHART (4-wire), replaces RS232Price on request
I1HHigh-temperature insertion transducers, up to +180 °CPrice on request
B1 / B1HSmall-pipe clamp-on transducers, DN15–DN40Price on request
Cable H2AExtra cable for H2A transducersPrice on request

Extra cable and pipe straps

CodeItemPrice (USD)
CABLE-80Extra transducer cable, up to +80 °C
Per metre, beyond the standard length
+US$5
CABLE-130Extra transducer cable, up to +130 °C
Per metre, beyond the standard length
+US$9
STRAP2Extra or spare 1.3 m pipe straps
Per pair. Two straps in the box fit pipes up to DN300; add pairs for larger pipes or as spares.
+US$11.50

Prices are per unit, excluding shipping and import duties, for 1–9 units. For 10 units or more, email info@segmensensor.com and our engineers will recalculate the price for your quantity.

How do I install the U11?

The U11 installs from outside the pipe in four steps, with no cutting and no shutdown. The diagrams come from the U11 user manual.

  1. Mount the back frame

    Fit the back frame to the transmitter, vertical or horizontal, then fix it to the wall with expansion screws in Ø6 mm holes at 228 × 178 mm.

  2. Choose a straight, full pipe

    After a 90° bend, leave at least 10 pipe diameters upstream and 5 downstream. Valves and pumps need longer runs — see the manual.

  3. Strap on the transducers

    Mount them at 3 or 9 o'clock on horizontal pipes, never at the top or bottom. V method is standard; Z method gives a stronger signal on large pipes.

  4. Enter the pipe data

    Key in the pipe size, material and liquid. The meter shows the transducer spacing; set it and read the flow.

Watch the clamp-on installation video

U11 installation diagrams from the user manual: back frame with 6 mm holes at 228 x 178 mm, V and Z transducer mounting, straight pipe after a 90 degree bend
U11 dimension drawing: transmitter 254 x 230 x 64 mm, clamp-on transducer 68 x 34 x 34 mm, insertion transducer 260.5 mm with G1 inch thread

U11 dimensions

Transmitter254 × 230 × 64 mm (W × H × D)
Clamp-on transducer (A2, H1A, H2A)68 × 34 × 34 mm
Insertion transducer (I1)Length 260.5 mm, G1" thread
Wall mountingBack frame, Ø6 mm holes at 228 × 178 mm

Source: SEGMENsensor U11 datasheet drawing.

U11 specifications

Pipe size15–5000 mm depending on transducer; DN25–DN1200 with one pair of A2, H1A or H2A clamp-on transducers (the configurations on this page)
Flow velocity±0.01 to ±12 m/s
Accuracy±0.5%
Repeatability0.1%
LiquidSingle, sound-conducting liquid in a full pipe
Signal processingFPGA chip with TGA algorithm; tolerates intermittent bubbles or particles for up to 5 s; samples up to 300 times per second
OutputsChoose 2 of 5: 4–20 mA (max. load 750 Ω); pulse / OCT 0–9999 Hz, adjustable min. and max. frequency; relay SPST, max. 1 Hz (0.4 A @ 125 V AC or 2 A @ 30 V DC); RS232 Modbus; RS485 Modbus
Communication optionHART (replaces RS232) — price on request
Power supply90–245 V AC, 48–63 Hz, or 10–36 V DC
ProtectionTransducers IP68
Transducer temperatureA2 −40 to +80 °C; H1A −40 to +130 °C; H2A −40 to +180 °C; I1 −40 to +130 °C
Data loggingFcard, expandable to 32 GB
Transducer cable9 m standard; custom up to 274 m
CertificationsCE, UKCA — EMC tested to EN IEC 61000-6-2 and EN IEC 61000-6-4 (certificate copies on request)

Source: SEGMENsensor U11 datasheet.

Spare parts for the U11

Order replacement transducers, temperature sensors and installation parts for the U11 on their own. Prices are per item, excluding shipping and import duties.

CodePartPrice (USD)Qty
SP-A2Pair of A2 clamp-on transducers
−40 to +80 °C, 9 m cable.
Standard item: One pair comes with the A2 configuration.
US$289
SP-H1APair of H1A clamp-on transducers
−40 to +130 °C, 9 m cable.
Standard item: One pair comes with the H1A configuration.
US$479
SP-H2APair of H2A clamp-on transducers
Up to +180 °C, 9 m cable.
Standard item: One pair comes with the H2A configuration.
US$899
SP-I1Pair of I1 insertion transducers
−40 to +130 °C, with mounting base and ball valve, 9 m cable.
Standard item: One pair comes with the I1 configuration.
US$479
SP-I1HPair of I1H high-temperature insertion transducers
Up to +180 °C, with mounting base and ball valve, 9 m cable.
Standard item: One pair comes with the I1H configuration.
US$2,049
SP-PT1000Pair of clamp-on PT1000 temperature sensors
For the energy (BTU) version, 9 m cable.
US$139
SP-ENCTransmitter enclosure
Replacement U11 housing.
US$389
SP-MNTMounting kit
Back frame and fixings for the U11 transmitter.
Standard item: Supplied with every meter.
US$29
SP-STPair of stainless-steel pipe straps, 1.3 m
Join onto the standard straps for pipes above DN300, or keep as spares.
Standard item: 2 straps (1 pair) come with every meter.
US$11.50
SP-CPLCoupling compound, one tube
For mounting or re-mounting clamp-on transducers.
Standard item: Coupling compound comes with every meter.
US$11.50

Spare parts ship from our factory within 2 weeks of payment by UPS; shipping is added at checkout. Not sure which part fits? Email info@segmensensor.com with your meter's part number.

Shipping, duties and delivery

Frequently asked questions

Will the U11 work on my pipe?

The U11 measures full pipes carrying a single, sound-conducting liquid such as water or chilled water. The clamp-on configurations on this page cover DN25–DN1200 at up to +80 °C (A2), +130 °C (H1A) or +180 °C (H2A). If you are unsure, send us the pipe size, material, liquid and temperature and our engineers will reply by email within one working day.

How is the U11 different from the U10?

The U11 is the high-accuracy model: ±0.5% and 0.1% repeatability against ±1% and 0.2% for the U10, a wider velocity range of ±0.01 to ±12 m/s, AC or DC power, and an FPGA-based signal processor that rides through bubbles or particles for up to 5 s. Choose the U10 when ±1% is enough for the job.

What does the price include?

The price is per unit and includes the transmitter with its back frame, one pair of transducers with cable, two 1.3 m pipe straps for pipes up to DN300, coupling compound, the user manual and a factory calibration report. UPS shipping is added at checkout. Import duty and tax are not included; you pay them in your country on import.

My pipe is larger than DN300. How many straps do I need?

The two pipe straps in the box are 1.3 m long and fit pipes up to DN300. Each transducer is held by one strap loop around the pipe, and the loop needs about 3.14 × the pipe outside diameter, plus a little to tighten. Extra straps are the same 1.3 m straps and join onto the standard ones, so every extra pair adds 1.3 m to both loops. Work out what your pipe needs and choose the number of extra pairs in step 1 of the configurator; they are charged per pair, and the price is shown before you pay. If your pipe is DN300 or smaller and you want spares, add spare pairs of 1.3 m straps under Options in step 3.

Can the U11 measure heating or cooling energy?

Yes. Add the energy (BTU) option in step 3: it fits an RTD module and a pair of clamp-on PT1000 temperature sensors with 9 m cable, and the meter then calculates heating or cooling energy from flow and the supply and return temperatures.

Which outputs can I have?

Two of five outputs are wired at the factory: 4–20 mA, pulse / OCT, relay, RS232 Modbus or RS485 Modbus. You choose the two in the configurator, at no extra cost. HART is available on request and replaces RS232; email us for the price.

Do I pay import duty when the meter arrives?

Yes. Import duty, VAT or GST and any customs fees are paid by you as the importer, and the rates depend on your country. UPS or your customs broker will ask for payment before or at delivery. We send the commercial invoice and packing list with the shipment and by email, and help with customs questions about the product.

When will my order arrive?

We ship from our factory within 2 weeks of payment. UPS then usually takes 3–5 working days to deliver. The configurator shows an estimated delivery date before you pay.

Can I order 10 or more units?

Yes. For 10 units or more, email info@segmensensor.com with the part number and quantity. Our engineers recalculate the price for your quantity and reply by email.

Distributor or reseller? See what it takes to become a SEGMENsensor distributor →

Not sure the U11 fits your pipe?

Send us the pipe size and material, the liquid and its temperature. Our engineers reply by email within one working day.

Email only · info@segmensensor.com

info@segmensensor.com