Flow rate equals mean velocity times pipe area: Q = v × πD²/4, with D the inside diameter. In practical units, m³/h = 0.0028274 × m/s × mm² and US gpm = 2.448 × ft/s × in². Example: water at 2 m/s in a 50 mm bore flows at 14.14 m³/h (235.6 L/min, 62.2 US gpm).
Pipe flow rate calculator
Assumes a full, circular pipe and the mean (area-averaged) velocity. Exact factors: 1 in = 25.4 mm, 1 ft = 0.3048 m, US gallon = 3.785 411 784 L (NIST SP 811). Results rounded to 4 significant figures.
What is the formula for flow rate from velocity?
Volumetric flow rate is the mean velocity multiplied by the flow area: Q = v × A. For a full circular pipe the area is A = π × D² ÷ 4, where D is the inside diameter. Keep units consistent — metres and m/s give m³/s — then convert to the unit you need.
General: Q = v × π × D² ÷ 4 (SI: Q in m³/s, v in m/s, D in m)
Metric shortcut: Qm³/h = 0.002 827 4 × vm/s × Dmm² · QL/min = 0.047 124 × vm/s × Dmm²
US shortcut: QUS gpm = 2.448 × vft/s × Din²
Velocity from flow: vm/s = 353.68 × Qm³/h ÷ Dmm² · vft/s = 0.4085 × Qgpm ÷ Din²
Where the shortcut constants come from: π/4 × 10−6 m²/mm² × 3600 s/h = 0.002 827 4; and π/4 ÷ 144 in²/ft² × 60 s/min × 7.480 52 US gal/ft³ = 2.448.
How does the calculation work, step by step?
- Find the inside diameter. If you only know the outside diameter, subtract two wall thicknesses (and any lining).
- Calculate the flow area with A = π × D² ÷ 4.
- Multiply by the mean velocity to get volumetric flow in m³/s (or ft³/s).
- Convert units: × 3600 for m³/h, × 60 000 for L/min, × 15 850.3 for US gpm.
Flow rate at 1 m/s by inside diameter
Because flow scales linearly with velocity, multiply any row by your velocity in m/s. Example: at 2.5 m/s, a 100 mm bore carries 2.5 × 28.27 = 70.7 m³/h.
| Inside diameter (mm) | m³/h at 1 m/s | L/min at 1 m/s | US gpm at 1 m/s |
|---|---|---|---|
| 15 | 0.636 | 10.6 | 2.80 |
| 20 | 1.131 | 18.8 | 4.98 |
| 25 | 1.767 | 29.5 | 7.78 |
| 32 | 2.895 | 48.3 | 12.75 |
| 40 | 4.524 | 75.4 | 19.92 |
| 50 | 7.069 | 117.8 | 31.12 |
| 65 | 11.95 | 199.1 | 52.60 |
| 80 | 18.10 | 301.6 | 79.67 |
| 100 | 28.27 | 471.2 | 124.5 |
| 150 | 63.62 | 1 060 | 280.1 |
| 200 | 113.1 | 1 885 | 498.0 |
| 300 | 254.5 | 4 241 | 1 120 |
| 500 | 706.9 | 11 781 | 3 112 |
Calculated values from Q = v × πD²/4; not meter ratings.
Worked examples
| Problem | Calculation | Result |
|---|---|---|
| 2 m/s in a 50 mm bore → flow | 0.0028274 × 2 × 50² | 14.14 m³/h = 235.6 L/min = 62.2 US gpm |
| 5 ft/s in a 4.026 in bore (4-inch Schedule 40 steel) → flow | 2.448 × 5 × 4.026² | 198.4 US gpm = 45.1 m³/h |
| 30 m³/h in an 80 mm bore → velocity | 353.68 × 30 ÷ 80² | 1.66 m/s (5.44 ft/s) |
| OD 60.3 mm, wall 3.9 mm, 1.5 m/s → flow | D = 60.3 − 7.8 = 52.5 mm; 0.0028274 × 1.5 × 52.5² | 11.69 m³/h = 194.8 L/min |
Should I use the nominal or the inside diameter?
Use the inside diameter. Nominal size (DN or NPS) is a label, not a dimension: a 4-inch Schedule 40 steel pipe has a 4.026 in (102.3 mm) bore, so using "100 mm" understates the area by about 4.6 %. Wall schedule, material and lining all change the bore, and the error doubles from diameter to flow because area depends on D².
How does a clamp-on ultrasonic flow meter use this formula?
A transit-time clamp-on meter measures the liquid's velocity through the pipe wall and multiplies it by the flow area calculated from the pipe data you enter (outside diameter, wall thickness, material). That is why an accurate inside diameter matters as much as the sensor itself — see how a clamp-on ultrasonic flow meter works and how to install a clamp-on flow meter.
The table converts the published velocity ranges of two SEGMENsensor wall-mount meters into flow ranges for example bores. U10: ±0.03 to ±5 m/s, pipes 25–1200 mm, ±1 %. U11: ±0.01 to ±12 m/s, pipes 15–5000 mm, ±0.5 %.
| Inside diameter | U10 range (calculated, m³/h) | U11 range (calculated, m³/h) |
|---|---|---|
| 50 mm | 0.21 – 35.3 | 0.07 – 84.8 |
| 100 mm | 0.85 – 141.4 | 0.28 – 339.3 |
| 200 mm | 3.39 – 565.5 | 1.13 – 1 357 |
| 500 mm | 21.2 – 3 534 | 7.07 – 8 482 |
Velocity ranges and pipe sizes from the U10 / U11 datasheets; flow values are calculated with Q = v × πD²/4, not additional ratings. The one-piece U12 (DN15–DN65) and U13 (DN15–DN40) are specified in L/min per pipe size — see the flow unit converter for those ranges in m³/h and gpm.
Compare all six models in clamp-on ultrasonic flow meter models compared or open the clamp-on ultrasonic flow meter product page for datasheets. Need a wider measuring span? Read flow meter turndown ratio.
Buy online
Need one or a few clamp-on meters for a single site? The models below can be configured and bought online. For OEM volumes, private label or an engineering review, use the request form below.
Frequently Asked Questions
Q = v × A, where A = π × D² ÷ 4 for a full circular pipe and D is the inside diameter. With v in m/s and D in metres, Q is in m³/s; multiply by 3600 for m³/h.
Multiply 2.448 × velocity in ft/s × inside diameter in inches squared. Example: 5 ft/s in a 4.026 in bore = 2.448 × 5 × 16.21 = 198.4 US gpm.
Multiply 0.0028274 × velocity in m/s × inside diameter in mm squared. Example: 2 m/s in a 50 mm bore = 14.14 m³/h (235.6 L/min).
Inside diameter. A 4-inch Schedule 40 steel pipe has a 4.026 in (102.3 mm) bore; using 100 mm understates the flow by about 4.6 %, because area scales with the diameter squared.
Divide flow by area: v = Q ÷ (π × D² ÷ 4). In practical units, v in m/s = 353.68 × Q in m³/h ÷ D in mm squared; 30 m³/h in an 80 mm bore is 1.66 m/s.
Only if A is the wetted area, not the full bore, and v is the mean velocity of that wetted section. Clamp-on ultrasonic meters such as the SEGMENsensor U-series are intended for full pipes of a single, sound-conducting liquid.