Quick Answer

Flow rate equals mean velocity times pipe area: Q = v × πD²/4, with D the inside diameter. In practical units, m³/h = 0.0028274 × m/s × mm² and US gpm = 2.448 × ft/s × in². Example: water at 2 m/s in a 50 mm bore flows at 14.14 m³/h (235.6 L/min, 62.2 US gpm).

Pipe flow rate calculator

Assumes a full, circular pipe and the mean (area-averaged) velocity. Exact factors: 1 in = 25.4 mm, 1 ft = 0.3048 m, US gallon = 3.785 411 784 L (NIST SP 811). Results rounded to 4 significant figures.

What is the formula for flow rate from velocity?

Volumetric flow rate is the mean velocity multiplied by the flow area: Q = v × A. For a full circular pipe the area is A = π × D² ÷ 4, where D is the inside diameter. Keep units consistent — metres and m/s give m³/s — then convert to the unit you need.

General: Q = v × π × D² ÷ 4  (SI: Q in m³/s, v in m/s, D in m)

Metric shortcut: Qm³/h = 0.002 827 4 × vm/s × Dmm²  ·  QL/min = 0.047 124 × vm/s × Dmm²

US shortcut: QUS gpm = 2.448 × vft/s × Din²

Velocity from flow: vm/s = 353.68 × Qm³/h ÷ Dmm²  ·  vft/s = 0.4085 × Qgpm ÷ Din²

Where the shortcut constants come from: π/4 × 10−6 m²/mm² × 3600 s/h = 0.002 827 4; and π/4 ÷ 144 in²/ft² × 60 s/min × 7.480 52 US gal/ft³ = 2.448.

How does the calculation work, step by step?

Four steps from pipe size and velocity to flow rateStep 1: find the inside diameter, outside diameter minus two wall thicknesses. Step 2: area equals pi times D squared divided by 4. Step 3: multiply area by mean velocity. Step 4: convert cubic metres per second to cubic metres per hour, litres per minute or US gallons per minute. v D Mean velocity v across the inside diameter D Pipe wall (grey) is not part of the flow area 1 Inside diameterD = OD − 2 × wall thickness 2 Flow areaA = π × D² ÷ 4 3 Multiply by mean velocityQ = v × A (m/s × m² = m³/s) 4 Convert unitsm³/s × 3600 = m³/h · × 60 000 = L/min Illustration. Valid for a full circular pipe; unit factors per NIST SP 811.
Illustration: the four steps the calculator above performs.
  1. Find the inside diameter. If you only know the outside diameter, subtract two wall thicknesses (and any lining).
  2. Calculate the flow area with A = π × D² ÷ 4.
  3. Multiply by the mean velocity to get volumetric flow in m³/s (or ft³/s).
  4. Convert units: × 3600 for m³/h, × 60 000 for L/min, × 15 850.3 for US gpm.

Flow rate at 1 m/s by inside diameter

Because flow scales linearly with velocity, multiply any row by your velocity in m/s. Example: at 2.5 m/s, a 100 mm bore carries 2.5 × 28.27 = 70.7 m³/h.

Inside diameter (mm)m³/h at 1 m/sL/min at 1 m/sUS gpm at 1 m/s
150.63610.62.80
201.13118.84.98
251.76729.57.78
322.89548.312.75
404.52475.419.92
507.069117.831.12
6511.95199.152.60
8018.10301.679.67
10028.27471.2124.5
15063.621 060280.1
200113.11 885498.0
300254.54 2411 120
500706.911 7813 112

Calculated values from Q = v × πD²/4; not meter ratings.

Worked examples

ProblemCalculationResult
2 m/s in a 50 mm bore → flow0.0028274 × 2 × 50²14.14 m³/h = 235.6 L/min = 62.2 US gpm
5 ft/s in a 4.026 in bore (4-inch Schedule 40 steel) → flow2.448 × 5 × 4.026²198.4 US gpm = 45.1 m³/h
30 m³/h in an 80 mm bore → velocity353.68 × 30 ÷ 80²1.66 m/s (5.44 ft/s)
OD 60.3 mm, wall 3.9 mm, 1.5 m/s → flowD = 60.3 − 7.8 = 52.5 mm; 0.0028274 × 1.5 × 52.5²11.69 m³/h = 194.8 L/min

Should I use the nominal or the inside diameter?

Use the inside diameter. Nominal size (DN or NPS) is a label, not a dimension: a 4-inch Schedule 40 steel pipe has a 4.026 in (102.3 mm) bore, so using "100 mm" understates the area by about 4.6 %. Wall schedule, material and lining all change the bore, and the error doubles from diameter to flow because area depends on D².

How does a clamp-on ultrasonic flow meter use this formula?

A transit-time clamp-on meter measures the liquid's velocity through the pipe wall and multiplies it by the flow area calculated from the pipe data you enter (outside diameter, wall thickness, material). That is why an accurate inside diameter matters as much as the sensor itself — see how a clamp-on ultrasonic flow meter works and how to install a clamp-on flow meter.

The table converts the published velocity ranges of two SEGMENsensor wall-mount meters into flow ranges for example bores. U10: ±0.03 to ±5 m/s, pipes 25–1200 mm, ±1 %. U11: ±0.01 to ±12 m/s, pipes 15–5000 mm, ±0.5 %.

Inside diameterU10 range (calculated, m³/h)U11 range (calculated, m³/h)
50 mm0.21 – 35.30.07 – 84.8
100 mm0.85 – 141.40.28 – 339.3
200 mm3.39 – 565.51.13 – 1 357
500 mm21.2 – 3 5347.07 – 8 482

Velocity ranges and pipe sizes from the U10 / U11 datasheets; flow values are calculated with Q = v × πD²/4, not additional ratings. The one-piece U12 (DN15–DN65) and U13 (DN15–DN40) are specified in L/min per pipe size — see the flow unit converter for those ranges in m³/h and gpm.

Compare all six models in clamp-on ultrasonic flow meter models compared or open the clamp-on ultrasonic flow meter product page for datasheets. Need a wider measuring span? Read flow meter turndown ratio.

Buy online

Need one or a few clamp-on meters for a single site? The models below can be configured and bought online. For OEM volumes, private label or an engineering review, use the request form below.

U12One-piece · DN15–DN65Buy online →U13Small pipe · DN15–DN40Buy online →U10Wall-mount · 25–1200 mmBuy online →U10S PROColour display · 15–1200 mmBuy online →U11High accuracy ±0.5%Buy online →U20Portable · spot checksBuy online →

See all clamp-on flow meters you can buy online →

Standards & Further Reading

Frequently Asked Questions

Q = v × A, where A = π × D² ÷ 4 for a full circular pipe and D is the inside diameter. With v in m/s and D in metres, Q is in m³/s; multiply by 3600 for m³/h.

Multiply 2.448 × velocity in ft/s × inside diameter in inches squared. Example: 5 ft/s in a 4.026 in bore = 2.448 × 5 × 16.21 = 198.4 US gpm.

Multiply 0.0028274 × velocity in m/s × inside diameter in mm squared. Example: 2 m/s in a 50 mm bore = 14.14 m³/h (235.6 L/min).

Inside diameter. A 4-inch Schedule 40 steel pipe has a 4.026 in (102.3 mm) bore; using 100 mm understates the flow by about 4.6 %, because area scales with the diameter squared.

Divide flow by area: v = Q ÷ (π × D² ÷ 4). In practical units, v in m/s = 353.68 × Q in m³/h ÷ D in mm squared; 30 m³/h in an 80 mm bore is 1.66 m/s.

Only if A is the wetted area, not the full bore, and v is the mean velocity of that wetted section. Clamp-on ultrasonic meters such as the SEGMENsensor U-series are intended for full pipes of a single, sound-conducting liquid.