Many palm oil storage tanks are still checked by hand dipping. A continuous level transmitter gives a live reading in the control room instead. SEGMENsensor supplies SE-LX magnetostrictive level transmitters (200–8000 mm, two floats for oil–water interface), SGM-LS10 float sensors and submersible hydrostatic transmitters to Malaysian mills and bulking installations, with 4–20 mA or RS485 output.
Level readings support stock records, dispatch, overflow protection and water draining. Typical tanks:
Tall heated storage tanks where a rigid-rod or flexible-cable magnetostrictive transmitter replaces manual dipping.
Oil–water interface with a two-float SE-LX transmitter to see the oil layer and the water below.
Level and high-level alarms; float switches add an independent overflow alarm.
Kernel crushing plants with smaller tanks, where SGM-LS10 covers heights up to 8000 mm.
Large tank farms where SE-LX30 flexible cable suits limited headroom above the tank.
Submersible hydrostatic transmitters for POME ponds, water tanks and boiler feed tanks.
Magnetostrictive values come from the SE-LX and SGM-LS10 datasheets. Choose rod or cable by tank height and headroom.
Flameproof transmitter with local display, DN25/DN50/DN100 flange, 200–8000 mm, one float for level or two floats for level plus interface.
View SE-LX20 rigid rodSame electronics on a flexible cable for tall tanks with limited headroom, 200–8000 mm.
View SE-LX30 flexible cableClamps to an existing magnetic level indicator to add a 4–20 mA output without opening the tank.
View SE-LX10 strap-on25–8000 mm, repeatability ±0.005 mm, 4–20 mA / 0–10 V / RS485, IP68, 304 stainless steel.
View SGM-LS10 stainless sensorHydrostatic probe, 0–1 to 0–100 m water column, 4–20 mA, IP68 — reading depends on liquid density.
View Submersible level transmitterMagnetostrictive transmitters measure the float position, so density changes with temperature do not shift the reading. Hydrostatic transmitters measure pressure and need density compensation.
| Method | Recommended | Range | Resolution / repeatability | Installation | Notes |
|---|---|---|---|---|---|
| Magnetostrictive, rigid rod | SE-LX20 | 200–8000 mm | 1 mm or 0.1 mm / ±1 mm or ±0.1 mm | Top flange DN25–DN100 | Two floats for interface; probe to +250 °C in high-temperature version |
| Magnetostrictive, flexible cable | SE-LX30 | 200–8000 mm | 1 mm or 0.1 mm / ±1 mm or ±0.1 mm | Top flange, cable with weight | For limited headroom |
| Magnetostrictive, stainless | SGM-LS10 | 25–8000 mm | 16-bit D/A / ±0.005 mm | Top mounting | -40 to +85 °C; IP68 |
| Add output to existing gauge | SE-LX10 | 200–8000 mm | 1 mm or 0.1 mm | Strapped to magnetic level indicator | No tank opening |
| Hydrostatic | Submersible transmitter | 0–1 to 0–100 m water column | Per product page | Hung from top or side | Needs density compensation |
| Point alarm | Float switch | Point level | — | Top or side | Independent overflow alarm |
Magnetostrictive values are taken from the SGM / SE series datasheets (Rev A); other values from the linked product pages. Updated 2026-09-30.
Official references: MPOB — Codes of Practice (PDF) · MPOB — Draft Code of Practice for Mills, third edition (public consultation, PDF)
SEGMENsensor is a sensor manufacturer in Shenzhen, China. We ship to Malaysia from our factory; we have no local office or warehouse in Malaysia. Your freight forwarder or customs broker arranges international transport and import clearance.
Payment: 100% T/T in advance before production/shipment. Quotations are FOB China; international freight and import duties/taxes are not included. Full terms: Terms & Conditions.
Tell us your specification — our engineers reply within 24 hours.
Proximity, photoelectric and pressure sensors for E&E production lines, test equipment and facility systems.
Electronics Factory SensorsAll country pages: Export Markets.