SEGMENsensor supplies inductive proximity sensors, photoelectric sensors and pressure transmitters to electronics and semiconductor-equipment factories and machine builders in Malaysia. Housings run from M8 to M30 with NPN or PNP outputs, and small quantities for maintenance spares are welcome. We manufacture in Shenzhen, China and ship to Malaysia from one piece, with samples in 5–7 working days.
Electronics assembly, back-end semiconductor operations and their facility systems use large numbers of small discrete sensors plus a few analog process instruments.
Board presence, carrier position and conveyor stops with photoelectric and inductive sensors.
Tray, magazine and handler positions; slot sensors for edge and index detection.
Through-beam and diffuse photoelectric sensors for long conveyor spans and transfer points.
Chilled-water and process-cooling pressure with 4–20 mA pressure transmitters.
Tank level with magnetostrictive or submersible level sensors; SGM-LC10 PP/PFA for corrosive chemicals.
Standard M8/M12/M18 sensors ordered in small lots for machine builds and maintenance stock.
Choose the sensing principle first, then housing size, output type and connection. Each product page lists the full part-number range.
M8, M12, M18 and M30, NPN/PNP, shielded or unshielded, sensing distance 1–25 mm, IP67/IP68.
View Inductive proximity sensorsThrough-beam to 40 m, retro-reflective to 30 m, diffuse to 6 m and slot types 5–50 mm, NPN/PNP, 10–30 V DC, IP67.
View Photoelectric sensorsHigh-temperature, weld-field immune, high-pressure and analog 4–20 mA / 0–10 V types.
View Special-environment proximity sensorsCooling water, compressed air and vacuum lines: 0–0.1 bar to 0–400 bar, ±0.25% FS, 4–20 mA.
View Pressure transmittersPP head and PFA rod for chemical tanks: 25–1000 mm, 4–20 mA / RS485, IP68.
View SGM-LC10 corrosion-resistant level sensorNon-invasive flow on cooling and DI water lines, DN15–DN6000.
View Clamp-on ultrasonic flow metersEquivalent parts are chosen by housing size, thread, sensing distance, output and connection — send the existing label or datasheet and we match those parameters.
| Task | Recommended | Key parameters | Output | Notes |
|---|---|---|---|---|
| Metal target position (carriers, fixtures) | Inductive proximity sensor | M8–M30, Sn 1–25 mm | NPN / PNP, NO / NC | Shielded for flush mounting |
| Board or part presence at a distance | Diffuse photoelectric | Up to 6 m | NPN / PNP | No reflector needed |
| Long conveyor spans, dusty areas | Through-beam photoelectric | Up to 40 m | NPN / PNP | Highest signal margin |
| Edge and index detection | Slot photoelectric | 5–50 mm slot | NPN / PNP | Factory-aligned |
| Cooling water / compressed air pressure | Pressure transmitter | 0–0.1 to 0–400 bar | 4–20 mA | ±0.25% FS |
| Chemical tank level | SGM-LC10 | 25–1000 mm | 4–20 mA / RS485 | PP head, PFA rod and flange |
Magnetostrictive values are taken from the SGM / SE series datasheets (Rev A); other values from the linked product pages. Updated 2026-09-30.
Official references: MIDA — Electrical & Electronics industry · SIRIM QAS — Product Certification Scheme
SEGMENsensor is a sensor manufacturer in Shenzhen, China. We ship to Malaysia from our factory; we have no local office or warehouse in Malaysia. Your freight forwarder or customs broker arranges international transport and import clearance.
Payment: 100% T/T in advance before production/shipment. Quotations are FOB China; international freight and import duties/taxes are not included. Full terms: Terms & Conditions.
Tell us your specification — our engineers reply within 24 hours.
Magnetostrictive and hydrostatic level measurement for CPO storage, clarification and bulking tanks.
Palm Oil Tank Level MeasurementAll country pages: Export Markets.