Fixed Clamp-On Ultrasonic Flow Meter (U12): Installation and First Reading

Video · 1:13 · Published 2026-10-05 · SEGMENsensor Engineering Team · Last updated

Integrating flow into a PLC or SCADA? Send the pipe size and the output pair you need — we confirm the U12 configuration.

U12 one-piece clamp-on flow meter
DN15–DN65±2% (±1% after calibration)Any two of 4–20 mA, RS485 Modbus, OCT pulse, relay
Qualification samples: 1–5 pcs in 5–7 days · production lead time and MOQ confirmed with the quotation.

Real footage of the U12 clamp-on ultrasonic flow meter: mount the transmitter on the pipe, connect the transducer cables and power, enter the pipe OD and wall thickness with the front keys, check signal strength on the Status page and watch the first stable reading; 4–20 mA and RS485 Modbus connect it to a PLC or SCADA.

Chapters

  1. 0:00Introduction
  2. 0:05Mount on the pipe
  3. 0:17Connect cables and power
  4. 0:27Enter pipe data
  5. 0:37Signal check
  6. 0:47Stable reading
  7. 0:56Outputs to PLC / SCADA

Key points

  • The transmitter mounts directly on the pipe; transducers clamp to the outside, so the pipe is never cut.
  • Connect the transducer cables and the power supply.
  • Enter pipe outer diameter and wall thickness with the front keys.
  • The Status page shows signal strength and quality on both transducers.
  • 4–20 mA and RS485 Modbus outputs connect to a PLC or SCADA system.

Transcript

Fixed clamp-on ultrasonic flow meter: installation and first reading.

The transmitter mounts directly on the pipe. The transducers clamp to the outside, so the pipe is never cut and the liquid is never touched.

Connect the transducer cables and the power supply.

Using the front keys, enter the pipe outer diameter and wall thickness.

The Status page then shows signal strength and quality on both transducers.

At steady flow, the reading stays stable.

4–20 mA and RS485 Modbus outputs connect the meter to a PLC or SCADA system.

SEGMENsensor clamp-on ultrasonic flow meters. Request a quote at segmensensor.com.

Standards and references

Related pages

Integrating flow into a PLC or SCADA? Send the pipe size and the output pair you need — we confirm the U12 configuration.Get a quote →

Request a Quote — U12 one-piece clamp-on flow meter