U13 · compact · sold by pipe size

U13 Small-Pipe Clamp-On Ultrasonic Flow Meter

The SEGMENsensor U13 is a compact one-piece clamp-on ultrasonic flow meter for small pipes, sold by pipe size from DN15 to DN40. Its PP glass-fibre housing resists acids and alkalis, it outputs 4–20 mA and RS485 Modbus, and it ships from our factory within 2 weeks of payment.

  • DN15–DN40choose the meter for your pipe size
  • <3% FSaccuracy, <1.5% FS after calibration
  • 4–20 mA + RS485outputs included
  • PP glass fibreacid- and alkali-resistant housing
Price for selected configurationFrom US$379per unit · excl. shipping and import duties · same price for 1–9 units
  • Ships within 2 weeksMade to order and shipped from our factory within 2 weeks of payment.
  • Customs documents suppliedWe send the commercial invoice and packing list for your import clearance.
  • Calibration reportEvery meter is calibrated before it leaves the factory and ships with its report.
  • Engineers by emailReply within one working day, Mon–Fri 09:00–18:00 China time.

SEGMENsensor Engineering Team · Last updated: 1 November 2026

From order to your door

  1. TodayConfigure and pay

    Card, PayPal or bank transfer. UPS shipping is added at checkout; import duty and tax are not included.

  2. Within 2 weeksBuilt and calibrated

    Your meter is made to order, calibrated before it leaves the factory and packed in its own box.

  3. 3–5 working daysUPS

    Door to door from our factory to your company address, usually 3–5 working days.

  4. DeliveredYou clear customs

    You pay import duty and tax in your country, usually through UPS or your customs broker. We supply the commercial invoice and packing list.

Everything in the U13 box: meter, coupling pads, clamp screws, hex key and M12 signal cable

What's in the box

Standard configuration, included in the unit price:

  • U13 meter for the pipe size you choose
  • Coupling pads
  • Clamp screws and hex key
  • M12 signal cable, 2 m
  • User manual
  • Factory calibration report

Which transducer do I need?

Each U13 fits one pipe size, so pick the part number that matches your pipe's outside diameter. The flow range for each size is shown on its row. Add the B1H sensor in step 3 for liquid up to +105 °C. For any other size, email us.

Every standard configuration includes, in the unit price:
  • U13 meter for the pipe size you choose
  • Coupling pads
  • Clamp screws and hex key
  • M12 signal cable, 2 m
  • User manual
  • Factory calibration report
Your pipe and liquidPart numberTransducerCableUnit price (USD)
DN15 pipe, outside diameter 18–23 mmU13-DN150.55–60 L/min.2 mUS$379Select
DN20 pipe, outside diameter 23–28 mmU13-DN200.95–100 L/min.2 mUS$379Select
DN25 pipe, outside diameter 28–33 mmU13-DN251–150 L/min.2 mUS$379Select
DN32 pipe, outside diameter 33–44 mmU13-DN321.5–260 L/min. Larger housing.2 mUS$399Select
DN40 pipe, outside diameter 44–52 mmU13-DN402.5–400 L/min. Larger housing.2 mUS$399Select

Options — added to the unit price

CodeOptionPrice (USD)
B1HHigh-temperature sensor B1H
Sensor for liquid from −10 to +105 °C instead of +65 °C.
+US$99
OCT / RelayOCT pulse or one relay alarm outputPrice on request
CableLonger M12 cable, up to 5 mPrice on request
Other sizesPipe sizes outside DN15–DN40Price on request

Prices are per unit, excluding shipping and import duties, for 1–9 units. For 10 units or more, email info@segmensensor.com and our engineers will recalculate the price for your quantity.

How do I install the U13?

The U13 clamps onto the pipe in one piece and needs only two settings in the menu.

  1. Fit the coupling pad

    Remove the transparent protective film from the coupling pad on the meter.

  2. Place the bottom clamp

    Fit the bottom clamp against the pipe, then insert the guide shafts of the meter into the matching holes.

  3. Tighten the screws

    Lock the screws to fix the meter on the pipe. Do not over-tighten: that can damage the coupling pad.

  4. Set OD and wall thickness

    Enter the pipe outside diameter and wall thickness in the menu. The inner diameter must not fall below the lower limit for that size.

Watch the U13 installation video

U13 compact flow meter clamped on a small pipe, display showing the flow in litres per minute
U13 dimension drawing: DN15-DN25 version 50 mm wide, 82.6 mm high; DN32-DN40 version 70 mm wide, 107.5 mm high

U13 dimensions

DN15–DN25 versionWidth 50 mm, overall height 82.6 mm
DN32–DN40 versionWidth 70 mm, overall height 107.5 mm
ConnectorM12

Source: SEGMENsensor U13 datasheet drawing.

U13 specifications

Pipe sizeDN15–DN40, one meter per size
Flow rangeDN15 0.55–60; DN20 0.95–100; DN25 1–150; DN32 1.5–260; DN40 2.5–400 L/min
Flow velocity0.15–10 m/s
Accuracy<3% FS (<1.5% FS after calibration)
LiquidWater or another single liquid without solids or impurities, full pipe
Outputs4–20 mA and RS485 Modbus; OCT pulse or one relay alarm on request
Power supply20–28 V DC
Sensor temperatureB1: −10 to +65 °C; B1H: −10 to +105 °C
Display256 × 128 backlit LCD, shows flow and liquid temperature
Low-flow cut-off0.08 m/s
Response time0.5–60 s
Data storageEEPROM
Cable2 m M12 cable, up to 5 m
HousingPP glass fibre, acid- and alkali-resistant
CertificationsCE, UKCA — EMC tested to EN IEC 61000-6-2 and EN IEC 61000-6-4 (certificate copies on request)

Source: SEGMENsensor U13 datasheet.

Spare parts for the U13

For coupling pads, clamp screws, cables or other U13 parts, email info@segmensensor.com with your part number and we will quote by email.

Shipping, duties and delivery

Frequently asked questions

Which U13 do I need?

Measure the outside diameter of your pipe and pick the matching size: DN15 for 18–23 mm, DN20 for 23–28 mm, DN25 for 28–33 mm, DN32 for 33–44 mm and DN40 for 44–52 mm. Each meter fits one pipe size. For any other size, email us.

How is the U13 different from the U12?

The U13 is the smaller meter, in an acid- and alkali-resistant PP glass-fibre housing, sold by pipe size, with 4–20 mA and RS485 as standard. The U12 reads ±2% (±1% after calibration), lets you choose two of four outputs and reaches DN65 with an upgrade.

What does the price include?

The price is per unit and includes the U13 meter for your pipe size, coupling pads, clamp screws and hex key, a 2 m M12 signal cable, the user manual and a factory calibration report. UPS shipping is added at checkout. Import duty and tax are not included; you pay them in your country on import.

What power does the U13 need?

A 20–28 V DC supply, for example a standard 24 V DC control-panel supply.

Do I pay import duty when the meter arrives?

Yes. Import duty, VAT or GST and any customs fees are paid by you as the importer, and the rates depend on your country. UPS or your customs broker will ask for payment before or at delivery. We send the commercial invoice and packing list with the shipment and by email, and help with customs questions about the product.

When will my order arrive?

We ship from our factory within 2 weeks of payment. UPS then usually takes 3–5 working days to deliver. The configurator shows an estimated delivery date before you pay.

Can I order 10 or more units?

Yes. For 10 units or more, email info@segmensensor.com with the part number and quantity. Our engineers recalculate the price for your quantity and reply by email.

Distributor or reseller? See what it takes to become a SEGMENsensor distributor →

Not sure the U13 fits your pipe?

Send us the pipe size and material, the liquid and its temperature. Our engineers reply by email within one working day.

Email only · info@segmensensor.com

info@segmensensor.com