Capacitive proximity sensors · M18
M18 non-flush capacitive proximity sensors. Rated sensing distances adjustable 2–15 mm, 2–25 mm; NPN, PNP, AC/DC outputs; 2 m cable, M12 connector. 54 part numbers, each a fixed SEGMENsensor order code.

A SEGMENsensor M18 non-flush capacitive proximity sensor detects metal and non-metal targets without contact, in an M18 threaded housing. The SGC-GP18U family has 54 part numbers with rated sensing distances of adjustable 2–15 mm, 2–25 mm.
Quick answer
It is an M18 threaded sensor that detects metal and non-metal targets without contact. Non-flush mounting gives a protruding sensing face and longer range, but needs a metal-free zone around it. In SEGMENsensor data, the SGC-GP18U family covers adjustable 2–15 mm, 2–25 mm.
Model finder
Filter the 54 part numbers. Click Quote to add a part number to the quote form.
| Part number | Sensing distance | Output | Supply | Connection | Housing | |
|---|---|---|---|---|---|---|
| SGC-GP18U-A150NA-C2 | 2–15 mm (adj.) | NPN NO | 10–30 V DC | 2 m cable | Nickel-plated brass | Quote |
| SGC-GP18U-A150NA-C2-PL | 2–15 mm (adj.) | NPN NO | 10–30 V DC | 2 m cable | PBT | Quote |
| SGC-GP18U-A150NA-Q4 | 2–15 mm (adj.) | NPN NO | 10–30 V DC | M12 connector | Nickel-plated brass | Quote |
| SGC-GP18U-A150NA-Q4-PL | 2–15 mm (adj.) | NPN NO | 10–30 V DC | M12 connector | PBT | Quote |
| SGC-GP18U-A150NB-C2 | 2–15 mm (adj.) | NPN NC | 10–30 V DC | 2 m cable | Nickel-plated brass | Quote |
| SGC-GP18U-A150NB-C2-PL | 2–15 mm (adj.) | NPN NC | 10–30 V DC | 2 m cable | PBT | Quote |
| SGC-GP18U-A150NB-Q4 | 2–15 mm (adj.) | NPN NC | 10–30 V DC | M12 connector | Nickel-plated brass | Quote |
| SGC-GP18U-A150NB-Q4-PL | 2–15 mm (adj.) | NPN NC | 10–30 V DC | M12 connector | PBT | Quote |
| SGC-GP18U-A150NC-C2 | 2–15 mm (adj.) | NPN NO + NC | 10–30 V DC | 2 m cable | Nickel-plated brass | Quote |
| SGC-GP18U-A150NC-C2-PL | 2–15 mm (adj.) | NPN NO + NC | 10–30 V DC | 2 m cable | PBT | Quote |
| SGC-GP18U-A150NC-Q4 | 2–15 mm (adj.) | NPN NO + NC | 10–30 V DC | M12 connector | Nickel-plated brass | Quote |
| SGC-GP18U-A150NC-Q4-PL | 2–15 mm (adj.) | NPN NO + NC | 10–30 V DC | M12 connector | PBT | Quote |
| SGC-GP18U-A150PA-C2 | 2–15 mm (adj.) | PNP NO | 10–30 V DC | 2 m cable | Nickel-plated brass | Quote |
| SGC-GP18U-A150PA-C2-PL | 2–15 mm (adj.) | PNP NO | 10–30 V DC | 2 m cable | PBT | Quote |
| SGC-GP18U-A150PA-Q4 | 2–15 mm (adj.) | PNP NO | 10–30 V DC | M12 connector | Nickel-plated brass | Quote |
| SGC-GP18U-A150PA-Q4-PL | 2–15 mm (adj.) | PNP NO | 10–30 V DC | M12 connector | PBT | Quote |
| SGC-GP18U-A150PB-C2 | 2–15 mm (adj.) | PNP NC | 10–30 V DC | 2 m cable | Nickel-plated brass | Quote |
| SGC-GP18U-A150PB-C2-PL | 2–15 mm (adj.) | PNP NC | 10–30 V DC | 2 m cable | PBT | Quote |
| SGC-GP18U-A150PB-Q4 | 2–15 mm (adj.) | PNP NC | 10–30 V DC | M12 connector | Nickel-plated brass | Quote |
| SGC-GP18U-A150PB-Q4-PL | 2–15 mm (adj.) | PNP NC | 10–30 V DC | M12 connector | PBT | Quote |
| SGC-GP18U-A150PC-C2 | 2–15 mm (adj.) | PNP NO + NC | 10–30 V DC | 2 m cable | Nickel-plated brass | Quote |
| SGC-GP18U-A150PC-C2-PL | 2–15 mm (adj.) | PNP NO + NC | 10–30 V DC | 2 m cable | PBT | Quote |
| SGC-GP18U-A150PC-Q4 | 2–15 mm (adj.) | PNP NO + NC | 10–30 V DC | M12 connector | Nickel-plated brass | Quote |
| SGC-GP18U-A150PC-Q4-PL | 2–15 mm (adj.) | PNP NO + NC | 10–30 V DC | M12 connector | PBT | Quote |
| SGC-GP18U-A150UA-C2-3W | 2–15 mm (adj.) | AC/DC NO | 20–250 V AC/DC | 2 m cable (3-wire) | Nickel-plated brass | Quote |
| SGC-GP18U-A150UA-C2-3W-PL | 2–15 mm (adj.) | AC/DC NO | 20–250 V AC/DC | 2 m cable (3-wire) | PBT | Quote |
| SGC-GP18U-A150UA-Q4 | 2–15 mm (adj.) | AC/DC NO | 20–250 V AC/DC | M12 connector | Nickel-plated brass | Quote |
| SGC-GP18U-A150UA-Q4-PL | 2–15 mm (adj.) | AC/DC NO | 20–250 V AC/DC | M12 connector | PBT | Quote |
| SGC-GP18U-A150UB-C2-3W | 2–15 mm (adj.) | AC/DC NC | 20–250 V AC/DC | 2 m cable (3-wire) | Nickel-plated brass | Quote |
| SGC-GP18U-A150UB-Q4 | 2–15 mm (adj.) | AC/DC NC | 20–250 V AC/DC | M12 connector | Nickel-plated brass | Quote |
| SGC-GP18U-A150UB-Q4-PL | 2–15 mm (adj.) | AC/DC NC | 20–250 V AC/DC | M12 connector | PBT | Quote |
| SGC-GP18U-A250NA-C2 | 2–25 mm (adj.) | NPN NO | 10–30 V DC | 2 m cable | Nickel-plated brass | Quote |
| SGC-GP18U-A250NA-C2-PL | 2–25 mm (adj.) | NPN NO | 10–30 V DC | 2 m cable | PBT | Quote |
| SGC-GP18U-A250NA-Q4 | 2–25 mm (adj.) | NPN NO | 10–30 V DC | M12 connector | Nickel-plated brass | Quote |
| SGC-GP18U-A250NB-C2 | 2–25 mm (adj.) | NPN NC | 10–30 V DC | 2 m cable | Nickel-plated brass | Quote |
| SGC-GP18U-A250NB-C2-PL | 2–25 mm (adj.) | NPN NC | 10–30 V DC | 2 m cable | PBT | Quote |
| SGC-GP18U-A250NB-Q4 | 2–25 mm (adj.) | NPN NC | 10–30 V DC | M12 connector | Nickel-plated brass | Quote |
| SGC-GP18U-A250NB-Q4-PL | 2–25 mm (adj.) | NPN NC | 10–30 V DC | M12 connector | PBT | Quote |
| SGC-GP18U-A250NC-C2 | 2–25 mm (adj.) | NPN NO + NC | 10–30 V DC | 2 m cable | Nickel-plated brass | Quote |
| SGC-GP18U-A250NC-C2-PL | 2–25 mm (adj.) | NPN NO + NC | 10–30 V DC | 2 m cable | PBT | Quote |
| SGC-GP18U-A250NC-Q4 | 2–25 mm (adj.) | NPN NO + NC | 10–30 V DC | M12 connector | Nickel-plated brass | Quote |
| SGC-GP18U-A250NC-Q4-PL | 2–25 mm (adj.) | NPN NO + NC | 10–30 V DC | M12 connector | PBT | Quote |
| SGC-GP18U-A250PA-C2 | 2–25 mm (adj.) | PNP NO | 10–30 V DC | 2 m cable | Nickel-plated brass | Quote |
| SGC-GP18U-A250PA-C2-PL | 2–25 mm (adj.) | PNP NO | 10–30 V DC | 2 m cable | PBT | Quote |
| SGC-GP18U-A250PA-Q4 | 2–25 mm (adj.) | PNP NO | 10–30 V DC | M12 connector | Nickel-plated brass | Quote |
| SGC-GP18U-A250PA-Q4-PL | 2–25 mm (adj.) | PNP NO | 10–30 V DC | M12 connector | PBT | Quote |
| SGC-GP18U-A250PB-C2 | 2–25 mm (adj.) | PNP NC | 10–30 V DC | 2 m cable | Nickel-plated brass | Quote |
| SGC-GP18U-A250PB-C2-PL | 2–25 mm (adj.) | PNP NC | 10–30 V DC | 2 m cable | PBT | Quote |
| SGC-GP18U-A250PB-Q4 | 2–25 mm (adj.) | PNP NC | 10–30 V DC | M12 connector | Nickel-plated brass | Quote |
| SGC-GP18U-A250PB-Q4-PL | 2–25 mm (adj.) | PNP NC | 10–30 V DC | M12 connector | PBT | Quote |
| SGC-GP18U-A250PC-C2 | 2–25 mm (adj.) | PNP NO + NC | 10–30 V DC | 2 m cable | Nickel-plated brass | Quote |
| SGC-GP18U-A250PC-C2-PL | 2–25 mm (adj.) | PNP NO + NC | 10–30 V DC | 2 m cable | PBT | Quote |
| SGC-GP18U-A250PC-Q4 | 2–25 mm (adj.) | PNP NO + NC | 10–30 V DC | M12 connector | Nickel-plated brass | Quote |
| SGC-GP18U-A250PC-Q4-PL | 2–25 mm (adj.) | PNP NO + NC | 10–30 V DC | M12 connector | PBT | Quote |
Source: SEGMENsensor part-number master, 2026-11-10. Housing material is listed per part number.
Availability
Number of part numbers per output, supply and sensing distance. Each count includes all contacts, connections and housing versions.
| Output · supply | 2–15 mm (adj.) | 2–25 mm (adj.) |
|---|---|---|
| NPN / PNP 3-wire · 10–30 V DC | 24 | 23 |
| AC/DC · 20–250 V AC/DC | 7 | — |
| Total | 31 | 23 |
“—”: no standard part number; send your requirement for a project evaluation.
Selection
Part number guide
Mounting
Mount it so the sensing face protrudes beyond the bracket, and keep metal and neighbouring sensors out of the zone around and in front of the face. IEC 60947-5-2 classifies proximity switches as embeddable (flush) or non-embeddable (non-flush); the minimum clearances for each part number are on its dimension drawing.
Wiring
A PNP 3-wire sensor switches L+ to the load, an NPN 3-wire sensor switches the load to L−, and a DC 2-wire sensor is wired in series with the load like a mechanical switch.
Wire colours and the connector pin assignment are printed on the label and datasheet of each part number. M12 connectors with screw locking are specified in IEC 61076-2-101; proximity switch requirements, including connector annexes, in IEC 60947-5-2.
More detail: NPN vs PNP proximity sensor wiring · Sensing distance explained
Specifications
| Housing | M18 thread, Nickel-plated brass (28), PBT (26) |
| Mounting | Non-flush (non-embeddable) |
| Rated sensing distance | adjustable 2–15 mm, 2–25 mm |
| Outputs | NPN, PNP, AC/DC |
| Supply | 10–30 V DC, 20–250 V AC/DC |
| Connection | 2 m cable, M12 connector |
| Targets | Metal and non-metal materials |
| Other electrical data | Per part-number datasheet, sent with the quotation |
Download the SGC-GP18U family datasheet (PDF, 4 pages) — all part numbers, family data, wiring and mounting. Dimension drawings are sent on request.

Ordering
Qualification samples 1–5 pcs in 5–7 days; production planned around annual volume.
Production lead time and order quantity are confirmed with the quotation.
Contact us about OEM and private-label options.
FAQ
Capacitive sensors detect both metal and non-metal targets, for example liquids, wood, plastics and paper. The switching distance depends on the target material, so test with your actual material before fixing the position.
A non-flush (unshielded) sensor has a protruding sensing face and needs a metal-free zone around it, but reaches further than a flush model of the same size.
This family has 54 part numbers with these rated sensing distances: adjustable 2–15 mm, 2–25 mm.
Supply ranges in this family: 10–30 V DC, 20–250 V AC/DC.
Connection options: 2 m cable (27 models), M12 connector (27 models).
Yes. Each part number is one fixed configuration. Click Quote in the model table or enter the part number in the form; the datasheet and lead time are confirmed with the quotation.
Tell us your specification — our engineers reply within 24 hours.