Capacitive proximity sensors · M12

M12 Non-Flush Capacitive Proximity Sensors 1–8 mm

M12 non-flush capacitive proximity sensors. Rated sensing distances adjustable 1–6 mm, 1–8 mm, 2–6 mm; NPN, PNP outputs; 2 m cable, M12 connector. 35 part numbers, each a fixed SEGMENsensor order code.

Sensing distance
1–8 mm
Outputs
NPN · PNP
Connection
2 m cable · M12 connector
Part numbers
35
Rendering of a SEGMENsensor M12 non-flush capacitive proximity sensor with 2 m cable
Product appearance rendering (3D render, not a photograph): M12 non-flush, 2 m cable

Key facts

A SEGMENsensor M12 non-flush capacitive proximity sensor detects metal and non-metal targets without contact, in an M12 threaded housing. The SGC-GP12U family has 35 part numbers with rated sensing distances of adjustable 1–6 mm, 1–8 mm, 2–6 mm.

  • Rated sensing distances: adjustable 1–6 mm, 1–8 mm, 2–6 mm.
  • Supply: 10–30 V DC.
  • Outputs: NPN, PNP. 12 NPN/PNP models have complementary NO + NC outputs.
  • Connections: 2 m cable (23), M12 connector (12). Housing: Nickel-plated brass (23), PBT (12).
  • Qualification samples of 1–5 pcs ship in 5–7 days; production is planned around your annual volume.

Last updated · SEGMENsensor Engineering Team

Quick answer

What is an M12 non-flush capacitive proximity sensor?

It is an M12 threaded sensor that detects metal and non-metal targets without contact. Non-flush mounting gives a protruding sensing face and longer range, but needs a metal-free zone around it. In SEGMENsensor data, the SGC-GP12U family covers adjustable 1–6 mm, 1–8 mm, 2–6 mm.

Model finder

Find your M12 non-flush part number

Filter the 35 part numbers. Click Quote to add a part number to the quote form.

35 of 35 models
Part numberSensing distanceOutputSupplyConnectionHousing
SGC-GP12U-A060NA-C22–6 mm (adj.)NPN NO10–30 V DC2 m cableNickel-plated brassQuote
SGC-GP12U-A060NA-C2-PL1–6 mm (adj.)NPN NO10–30 V DC2 m cablePBTQuote
SGC-GP12U-A060NA-Q41–6 mm (adj.)NPN NO10–30 V DCM12 connectorNickel-plated brassQuote
SGC-GP12U-A060NB-C21–6 mm (adj.)NPN NC10–30 V DC2 m cableNickel-plated brassQuote
SGC-GP12U-A060NB-C2-PL1–6 mm (adj.)NPN NC10–30 V DC2 m cablePBTQuote
SGC-GP12U-A060NB-Q41–6 mm (adj.)NPN NC10–30 V DCM12 connectorNickel-plated brassQuote
SGC-GP12U-A060NC-C21–6 mm (adj.)NPN NO + NC10–30 V DC2 m cableNickel-plated brassQuote
SGC-GP12U-A060NC-C2-PL1–6 mm (adj.)NPN NO + NC10–30 V DC2 m cablePBTQuote
SGC-GP12U-A060NC-Q41–6 mm (adj.)NPN NO + NC10–30 V DCM12 connectorNickel-plated brassQuote
SGC-GP12U-A060PA-C21–6 mm (adj.)PNP NO10–30 V DC2 m cableNickel-plated brassQuote
SGC-GP12U-A060PA-C2-PL1–6 mm (adj.)PNP NO10–30 V DC2 m cablePBTQuote
SGC-GP12U-A060PA-Q41–6 mm (adj.)PNP NO10–30 V DCM12 connectorNickel-plated brassQuote
SGC-GP12U-A060PB-C2-PL1–6 mm (adj.)PNP NC10–30 V DC2 m cablePBTQuote
SGC-GP12U-A060PB-Q41–6 mm (adj.)PNP NC10–30 V DCM12 connectorNickel-plated brassQuote
SGC-GP12U-A060PC-C21–6 mm (adj.)PNP NO + NC10–30 V DC2 m cableNickel-plated brassQuote
SGC-GP12U-A060PC-C2-PL1–6 mm (adj.)PNP NO + NC10–30 V DC2 m cablePBTQuote
SGC-GP12U-A060PC-Q41–6 mm (adj.)PNP NO + NC10–30 V DCM12 connectorNickel-plated brassQuote
SGC-GP12U-A080NA-C21–8 mm (adj.)NPN NO10–30 V DC2 m cableNickel-plated brassQuote
SGC-GP12U-A080NA-C2-PL1–8 mm (adj.)NPN NO10–30 V DC2 m cablePBTQuote
SGC-GP12U-A080NA-Q41–8 mm (adj.)NPN NO10–30 V DCM12 connectorNickel-plated brassQuote
SGC-GP12U-A080NB-C21–8 mm (adj.)NPN NC10–30 V DC2 m cableNickel-plated brassQuote
SGC-GP12U-A080NB-C2-PL1–8 mm (adj.)NPN NC10–30 V DC2 m cablePBTQuote
SGC-GP12U-A080NB-Q41–8 mm (adj.)NPN NC10–30 V DCM12 connectorNickel-plated brassQuote
SGC-GP12U-A080NC-C21–8 mm (adj.)NPN NO + NC10–30 V DC2 m cableNickel-plated brassQuote
SGC-GP12U-A080NC-C2-PL1–8 mm (adj.)NPN NO + NC10–30 V DC2 m cablePBTQuote
SGC-GP12U-A080NC-Q41–8 mm (adj.)NPN NO + NC10–30 V DCM12 connectorNickel-plated brassQuote
SGC-GP12U-A080PA-C21–8 mm (adj.)PNP NO10–30 V DC2 m cableNickel-plated brassQuote
SGC-GP12U-A080PA-C2-PL1–8 mm (adj.)PNP NO10–30 V DC2 m cablePBTQuote
SGC-GP12U-A080PA-Q41–8 mm (adj.)PNP NO10–30 V DCM12 connectorNickel-plated brassQuote
SGC-GP12U-A080PB-C21–8 mm (adj.)PNP NC10–30 V DC2 m cableNickel-plated brassQuote
SGC-GP12U-A080PB-C2-PL1–8 mm (adj.)PNP NC10–30 V DC2 m cablePBTQuote
SGC-GP12U-A080PB-Q41–8 mm (adj.)PNP NC10–30 V DCM12 connectorNickel-plated brassQuote
SGC-GP12U-A080PC-C21–8 mm (adj.)PNP NO + NC10–30 V DC2 m cableNickel-plated brassQuote
SGC-GP12U-A080PC-C2-PL1–8 mm (adj.)PNP NO + NC10–30 V DC2 m cablePBTQuote
SGC-GP12U-A080PC-Q41–8 mm (adj.)PNP NO + NC10–30 V DCM12 connectorNickel-plated brassQuote

Source: SEGMENsensor part-number master, 2026-11-10. Housing material is listed per part number.

Availability

Which combinations exist?

Number of part numbers per output, supply and sensing distance. Each count includes all contacts, connections and housing versions.

Output · supply1–6 mm (adj.)1–8 mm (adj.)
NPN / PNP 3-wire · 10–30 V DC1718
Total1718

“—”: no standard part number; send your requirement for a project evaluation.

Selection

How to choose

  1. Distance: choose from adjustable 1–6 mm, 1–8 mm, 2–6 mm so the target passes well inside the rated distance, not at its limit.
  2. Target material: test with the real material (liquid, plastic, wood, paper or metal), because the switching distance changes with the material.
  3. Output and supply: PNP or NPN to match the PLC input card.
  4. Contact: normally open or normally closed, or NO + NC when one sensor must give both signals.
  5. Connection and housing: 2 m cable, M12 connector.

Part number guide

Reading a SGC-GP12U part number

SGC-GP12U-A080PA-C2
SGCSEGMENsensor capacitive
GPGeneral-purpose series
12 · UM12 non-flush (S = flush)
A080Sensing distance in 0.1 mm: 1–8 mm (adj.); A = adjustable
P · APNP · NO (N = NPN, P = PNP, D = DC 2-wire, J = AC 2-wire, U = AC/DC; A = NO, B = NC, C = NO + NC)
C2C2 = 2 m cable, Q4 = M12 connector
+PL = plastic housing

Mounting

How do you mount a non-flush M12 sensor?

Mount it so the sensing face protrudes beyond the bracket, and keep metal and neighbouring sensors out of the zone around and in front of the face. IEC 60947-5-2 classifies proximity switches as embeddable (flush) or non-embeddable (non-flush); the minimum clearances for each part number are on its dimension drawing.

  1. Clamp the housing with the two lock nuts; do not hammer the housing.
  2. Check that no bracket edge, plate or second sensor is inside the clear zone.
  3. Power up and move the target into position to confirm the switching point before fixing the cable.
Mounting bracket Keep metal out of this zone Sensing face protrudes Target Sensing distance Schematic, not to scale
PNP 3-wireL+L−SensorOUTLoadNPN 3-wireL+L−SensorOUTLoadDC 2-wireL+L−SensorLoad

Wiring

How are PNP, NPN and 2-wire models connected?

A PNP 3-wire sensor switches L+ to the load, an NPN 3-wire sensor switches the load to L−, and a DC 2-wire sensor is wired in series with the load like a mechanical switch.

Wire colours and the connector pin assignment are printed on the label and datasheet of each part number. M12 connectors with screw locking are specified in IEC 61076-2-101; proximity switch requirements, including connector annexes, in IEC 60947-5-2.

More detail: NPN vs PNP proximity sensor wiring · Sensing distance explained

Specifications

Family data, SGC-GP12U

HousingM12 thread, Nickel-plated brass (23), PBT (12)
MountingNon-flush (non-embeddable)
Rated sensing distanceadjustable 1–6 mm, 1–8 mm, 2–6 mm
OutputsNPN, PNP
Supply10–30 V DC
Connection2 m cable, M12 connector
TargetsMetal and non-metal materials
Other electrical dataPer part-number datasheet, sent with the quotation

Download the SGC-GP12U family datasheet (PDF, 3 pages) — all part numbers, family data, wiring and mounting. Dimension drawings are sent on request.

Rendering of a SEGMENsensor M12 non-flush capacitive proximity sensor with M12 connector
Product appearance rendering (3D render, not a photograph): M12 non-flush, M12 connector

Ordering

Samples and OEM supply

Samples

Qualification samples 1–5 pcs in 5–7 days; production planned around annual volume.

Lead time and order quantity

Production lead time and order quantity are confirmed with the quotation.

OEM / private label

Contact us about OEM and private-label options.

FAQ

Common questions

What can an M12 capacitive proximity sensor detect?

Capacitive sensors detect both metal and non-metal targets, for example liquids, wood, plastics and paper. The switching distance depends on the target material, so test with your actual material before fixing the position.

What does non-flush mean for an M12 sensor?

A non-flush (unshielded) sensor has a protruding sensing face and needs a metal-free zone around it, but reaches further than a flush model of the same size.

Which sensing distances are available?

This family has 35 part numbers with these rated sensing distances: adjustable 1–6 mm, 1–8 mm, 2–6 mm.

Which supply voltages are available?

Supply ranges in this family: 10–30 V DC.

Which connections are available?

Connection options: 2 m cable (23 models), M12 connector (12 models).

Can I order with the SEGMENsensor part number?

Yes. Each part number is one fixed configuration. Click Quote in the model table or enter the part number in the form; the datasheet and lead time are confirmed with the quotation.

Request a Quote for M12 Non-Flush Capacitive Proximity Sensors (SGC-GP12U)

Tell us your specification — our engineers reply within 24 hours.

OEM volume supply · samples in 5–7 days · info@segmensensor.com

Related Products

Related Proximity Sensors

info@segmensensor.com