SEGMENsensor LVDT gauging probe sensors are precision displacement transducers designed for automated dimensional measurement, 100% in-process inspection, and coordinate gauging fixtures. The hardened probe tip (ruby ball, carbide, or flat) rides directly on the workpiece surface. Stroke 5–50 mm. Linearity ±0.05% FS. AC LVDT output or integrated 4-20mA/0-10V signal conditioner. Stainless steel housing. CE certified. OEM from Shenzhen since 2019, OEM volume supply.
A SEGMENsensor LVDT gauging probe is a precision displacement transducer whose ruby, carbide or flat tip touches the workpiece directly, for automated dimensional inspection and gauging fixtures. The tip moves the LVDT core, and the probe outputs an AC differential signal or a conditioned 4-20 mA / 0-10 V signal over strokes of 5–50 mm.
LVDT displacement sensors: how to choose one, mount it, and wire it. An LVDT has one primary coil and two secondary coils. A movable core changes how strongly they couple, so the output follows the core position, with no contact and no wear. With the core in the centre, the null point, the two secondary signals cancel. Move the core either way and the output rises, and its sign tells you the direction. There are three main types. Gauging probes have a spring-loaded tip for dimension checks, with ranges from ±0.5 mm to ±5 mm. Separate-core LVDTs, where the core rides on the moving part, cover ±2 to ±100 mm. Pen-type sensors with a built-in conditioner reach ±500 mm. Next, choose the output. An AC LVDT needs an external excitation of 1–10 kHz and a signal conditioner. A DC LVDT has the electronics built in. Supply 10–30 V DC, and read 4–20 mA, 0–10 V, or RS485 Modbus directly. Mounting. Centre the core in the bore so it never rubs the tube, and keep side loads off the probe. Clamp the body on its housing without over-tightening, so the housing is not deformed. For a ± range, set the reference position at the centre: the output reads zero, or 12 mA on a 4–20 mA output. Wiring a DC LVDT: supply + and 0 V, and the signal to the PLC analog input. Use shielded cable and ground the shield at one end only. An AC LVDT connects to a signal conditioner: its excitation output drives the primary, and the two secondaries return to its input. Keep the cable away from motor and drive cables. Before you order, specify the stroke, linearity, output, supply, temperature and connection. Linearity is ±0.25% FS as standard, or ±0.1% FS for high accuracy. SEGMENsensor makes gauging probes, separate-core and pen-type LVDTs, in 303 or 316L stainless steel, rated IP67. SEGMENsensor LVDT sensors. OEM volume supply. Datasheets and quotes at segmensensor.com.
What is an LVDT, and how does it measure position? An LVDT has three coils: a primary coil in the middle, and a secondary coil on each side. A movable core slides inside, on a push rod. An AC voltage excites the primary. With the core centred, both secondaries pick up equal voltages, and the difference is zero. When the core moves, one secondary couples more strongly than the other. The size of the difference shows how far the core moved, and its phase shows the direction. Electronics turn this into a DC signal, such as 4–20 mA. The core never touches the coils, so there is no wear. SEGMENsensor LVDT sensors: strokes from ±0.5 mm to ±500 mm. Learn more at segmensensor.com.
An LVDT gauging probe sensor is a Linear Variable Differential Transformer packaged as a precision measurement probe for contact dimensional gauging applications. Unlike position measurement LVDTs that couple the core to a moving machine part, a gauging probe LVDT has an exposed probe tip (ruby, carbide, or flat steel) on the extending rod that directly contacts the part surface being measured. The probe tip displacement drives the LVDT core, producing a voltage (AC) or conditioned current (4-20mA) signal proportional to the dimension. Gauging LVDTs are the reference-grade sensors in automated gauging fixtures, post-process inspection cells, and inline quality control systems for precision machined components.
Standard and reference-grade configurations. AC LVDT and DC conditioned (4-20mA / 0-10V) output options. All models CE and RoHS certified.
| Parameter | Value / Options |
|---|---|
| Measurement Principle | LVDT (Linear Variable Differential Transformer) |
| Probe Type | Free (unconstrained) probe / Spring-loaded option |
| Stroke Range | 5 mm / 10 mm / 25 mm / 50 mm |
| Linearity | ±0.05% FS (standard) / ±0.02% FS (reference grade) |
| Hysteresis | <0.01% FS |
| Resolution | Infinite (analog) / 0.1 µm (with 16-bit conditioner) |
| Output (AC) | ±3V AC differential (5V primary excitation, 2–10 kHz) |
| Output (DC) | 4-20mA (2-wire) / 0-5V / 0-10V / ±5V (3-wire) |
| Supply Voltage (DC) | 15–30V DC (conditioned) |
| Probe Tip Options | Hardened ruby ball (1 mm or 2 mm dia.) / Tungsten carbide ball / Flat disc / Needle |
| Probe Rod | Stainless steel hardened, ∅5 mm or ∅8 mm |
| Housing Material | Stainless steel 316L |
| Housing Diameter | 8 mm / 12 mm (gauge body standard) |
| Thread | M8 / M12 (for fixture mounting) |
| Operating Temperature | 0°C to +60°C (calibrated range) |
| Thermal Coefficient | <50 ppm/°C (full output span) |
| Connector | M12 4-pin (DC) / Flying lead (AC) |
| Samples | Samples 1–5 pcs for qualification; volume per project |
| Lead Time | Confirmed with the quotation |
| Certifications | CE, RoHS |
Measuring ranges, linearity, output options, core and spring-loaded versions, housing dimensions, connectors, temperature limits and the ordering code. No registration required.
The values below are the same as the specification table above, with inch and °F conversions added for US and UK fixture drawings. Conversions are calculated values (1 in = 25.4 mm).
A spring-loaded LVDT gauging probe has an internal return spring that pushes the probe rod out, so the ruby or carbide tip stays in contact with the part and follows its surface; the part pushes the rod back and the LVDT core reports how far. A free (unconstrained) probe has no return spring: the fixture, an actuator or the moving part sets the rod position. SEGMENsensor gauging probes are supplied as free probes with a spring-loaded option, on the same strokes, tips and outputs listed above.
| Point | Spring-loaded gauging probe | Free (unconstrained) probe |
|---|---|---|
| How the tip meets the part | Return spring extends the rod; tip rests on the surface | Fixture, actuator or the moving part positions the rod |
| Typical use | Diameter, height, thickness and runout checks in gauging fixtures; surface following | Positions where the rod is coupled to a moving part, or contact is set by the fixture |
| Mounting | Clamp the ∅8 / ∅12 mm body or use the M8 / M12 thread; keep the rod axis normal to the surface | Same body and thread; align the coupling so there is no side load on the rod |
| Contact force | Set by the spring; the value for your part and tip is confirmed per project | Set by your fixture |
| What to specify | Stroke (5 / 10 / 25 / 50 mm), linearity grade, tip type, AC or DC output, connector, body diameter and annual volume | |
For a self-retracting LVDT used outside gauging fixtures, see the spring-loaded LVDT sensor page. For the operating principle behind both types, read What is an LVDT sensor?
Request qualification samples for your gauging fixture
Qualification samples are 1–5 pcs and ship in 5–7 working days; production lead time and MOQ are confirmed with the quotation. Send your stroke, tip and output and we reply within 24 hours.
Three output and grade options to match your measurement system, PLC architecture, and tolerance requirements.
From automotive engine components to aerospace turbine blades — LVDT gauging probes deliver reference-grade dimensional measurement across industries.
Three steps from fixture installation to automated accept/reject output in a production gauging cell.
Every LVDT gauging probe ships with factory calibration data, CE declaration, and RoHS compliance certificate.
Technical and sourcing questions from OEM buyers and quality engineers about LVDT gauging probe sensors.
Tell us your stroke, required linearity, probe tip type, and output signal — we'll send a quote, datasheet, and fixture integration note within 24 hours.
Tell us your specification — our engineers reply within 24 hours.
Complete your dimensional measurement and quality control solution with SEGMENsensor's complementary product lines.
What usually ships with an LVDT gauging probe project. Configurations are confirmed with the quotation.