U10 Clamp-On Ultrasonic Flow Meter
The SEGMENsensor U10 is a wall-mount, transit-time clamp-on ultrasonic flow meter for full pipes of water or another clean liquid. It measures from outside the pipe with ±1% accuracy on DN25–DN1200, or DN15–DN40 with small-pipe transducers, and ships from our factory within 2 weeks of payment.
- ±1%accuracy, 0.2% repeatability
- DN15–DN1200pipe range, by transducer
- 2 of 5outputs included: 4–20 mA, pulse, Modbus, OCT, relay
- IP65 / IP68transmitter / transducers
- Ships within 2 weeksMade to order and shipped from our factory within 2 weeks of payment.
- Customs documents suppliedWe send the commercial invoice and packing list for your import clearance.
- Calibration reportEvery meter is calibrated before it leaves the factory and ships with its report.
- Engineers by emailReply within one working day, Mon–Fri 09:00–18:00 China time.
From order to your door
- TodayConfigure and pay
Card, PayPal or bank transfer. UPS shipping is added at checkout; import duty and tax are not included.
- Within 2 weeksBuilt and calibrated
Your meter is made to order, calibrated before it leaves the factory and packed in its own box.
- 3–5 working daysUPS
Door to door from our factory to your company address, usually 3–5 working days.
- DeliveredYou clear customs
You pay import duty and tax in your country, usually through UPS or your customs broker. We supply the commercial invoice and packing list.

What's in the box
Standard configuration, included in the unit price:
- U10 transmitter (wall-mount)
- One pair of transducers with cable — the configuration you choose
- Two 1.3 m pipe straps (fit pipes up to DN300) and coupling compound
- User manual
- Factory calibration report
- Any options you add, such as PT1000 temperature sensors or the small-pipe bracket
Which transducer do I need?
Choose A2 for DN25–DN1200 up to +80 °C, H1A for hotter liquid up to +130 °C, and B1 or B1H for small pipes DN15–DN40. Every configuration is the U10 transmitter with one pair of transducers; options and extra cable are added on top.
- U10 transmitter (wall-mount)
- One pair of transducers with cable
- Two 1.3 m pipe straps (fit pipes up to DN300) and coupling compound
- User manual
- Factory calibration report
| Your pipe and liquid | Part number | Transducer | Cable | Unit price (USD) | |
|---|---|---|---|---|---|
| DN25–DN1200, liquid up to +80 °C | U10-A2 | Standard A2 clamp-on transducers. One pair covers the whole range; for pipes above DN300 you add extra straps. | 9 m | US$449 | Select |
| DN25–DN1200, +80 to +130 °C | U10-H1A | High-temperature H1A transducers for hot water and condensate lines. For pipes above DN300 you add extra straps. | 9 m | US$549 | Select |
| DN15–DN40, 0 to +65 °C | U10-B1 | 2 MHz small-pipe transducers, 5 m cable. | 5 m | US$499 | Select |
| DN15–DN40, up to +115 °C | U10-B1H | High-temperature small-pipe transducers, 5 m cable. | 5 m | US$599 | Select |
| Clamp-on not suitable | U10-I1 | Insertion transducers, −40 to +130 °C. Our engineers confirm the installation for your pipe before the meter ships. | 9 m | US$549 | Select |
Options — added to the unit price
| Code | Option | Price (USD) |
|---|---|---|
AC | AC power supply 90–245 V | +US$49 |
E | Energy (BTU) meter, clamp-on PT1000 | +US$179 |
EI | Energy (BTU) meter, insertion PT1000 | +US$229 |
SD32 | 32 GB SD card data logging | +US$49 |
BR | Small-pipe mounting bracket | +US$109 |
POE | Power over Ethernet (PoE) | +US$179 |
MB | M-Bus output (EU version) | +US$169 |
HT | HART (4-wire) | +US$279 |
Extra cable and pipe straps
| Code | Item | Price (USD) |
|---|---|---|
CABLE-80 | Extra transducer cable, up to +80 °C | +US$3 |
CABLE-130 | Extra transducer cable, up to +130 °C | +US$5 |
CABLE-PT | Extra PT1000 cable | +US$3 |
STRAP2 | Extra or spare 1.3 m pipe straps | +US$11.50 |
- Transducer cable: 9 m standard (B1 / B1H small-pipe transducers: 5 m).
- Insertion transducers: tell us the pipe material so the mounting base matches it. Standard pressure rating 1.6 MPa.
How do I install the U10?
The U10 installs from outside the pipe in four steps, with no cutting and no shutdown. The diagrams come from the U10 user manual.
- Fix the bracket to the wall
The metal bracket has Ø6 mm holes at 100 mm centres. Slide the transmitter onto it and secure it with the screw under the cover.
- Choose a straight, full pipe
After a 90° bend, leave at least 10 pipe diameters upstream and 5 downstream. Valves and pumps need longer runs — see the manual.
- Strap on the transducers
Mount them at 3 or 9 o'clock on horizontal pipes, never at the top or bottom. V method is standard; Z method gives a stronger signal on large pipes.
- Enter the pipe data
Key in the pipe size, material and liquid. The meter shows the transducer spacing; set it and read the flow.


U10 dimensions
| Transmitter | 217.8 × 185 × 64 mm (W × H × D) |
|---|---|
| Clamp-on transducer (A2, H1A) | 64 × 30 × 27 mm |
| Insertion transducer (I1) | Length 260.5 mm, G1" thread |
U10 specifications
| Pipe size | DN25–DN1200 (A2, H1A); DN15–DN40 (B1, B1H) |
|---|---|
| Flow velocity | ±0.03 to ±5 m/s |
| Accuracy | ±1% |
| Repeatability | 0.2% |
| Linearity | ±1% |
| Liquid | Water (small amounts of air bubbles allowed); single, clean liquids in full pipes |
| Outputs | Choose 2 of 5: 4–20 mA (max. load 750 Ω), pulse 0–10 kHz, RS232 / RS485 Modbus, OCT, relay |
| Power supply | 10–36 V DC; 90–245 V AC optional |
| Protection | Transmitter IP65; transducers IP68 |
| Data logging | 32 GB SD card optional |
| Communication option | HART |
| Transducer cable | 9 m standard (B1 / B1H: 5 m); custom up to 274 m |
| Housing | Plastic wall-mount enclosure, external keypad |
| Certifications | CE, UKCA — EMC tested to EN IEC 61000-6-2 and EN IEC 61000-6-4 (certificate copies on request) |
Spare parts for the U10
Order replacement transducers, temperature sensors and installation parts for the U10 on their own. Prices are per item, excluding shipping and import duties.
| Code | Part | Price (USD) | Qty |
|---|---|---|---|
SP-A2 | Pair of A2 clamp-on transducers Standard item: One pair comes with the A2 configuration. | US$219 | |
SP-H1A | Pair of H1A clamp-on transducers Standard item: One pair comes with the H1A configuration. | US$479 | |
SP-I1 | Pair of I1 insertion transducers Standard item: One pair comes with the I1 configuration. | US$479 | |
SP-PT1000 | Pair of clamp-on PT1000 temperature sensors | US$139 | |
SP-ENC | Transmitter enclosure | US$29 | |
SP-BKT | Wall mounting bracket Standard item: Supplied with every meter. | US$9 | |
SP-ST | Pair of stainless-steel pipe straps, 1.3 m Standard item: 2 straps (1 pair) come with every meter. | US$11.50 | |
SP-CPL | Coupling compound, one tube Standard item: Coupling compound comes with every meter. | US$11.50 |
Shipping, duties and delivery
- We ship from our factory in China within 2 weeks of payment. Every meter ships in its own box.
- UPS delivers door to door, usually in 3–5 working days after dispatch. The UPS shipping cost is shown at checkout and paid with your order.
- Import duty, VAT or GST and any customs fees are not included in the price or the checkout total. You pay them as the importer in your country, and the rates differ by country.
- We help with customs clearance: the commercial invoice and packing list go with the shipment and by email, and our engineers answer customs questions about the product.
- Prices on this page are per unit, excluding shipping and import duties, for 1–9 units. For 10 units or more, email info@segmensensor.com and we will recalculate the price for your quantity.
Frequently asked questions
Will the U10 work on my pipe?
The U10 measures full pipes carrying water or another single, clean liquid. It covers DN25–DN1200 with the A2 or H1A transducers and DN15–DN40 with B1 or B1H. If you are unsure, send us the pipe size, material, liquid and temperature and our engineers will reply by email within one working day.
What does the price include?
The price is per unit and includes the transmitter, one pair of transducers with cable, two 1.3 m pipe straps for pipes up to DN300, coupling compound, the user manual and a factory calibration report. UPS shipping is added at checkout. Import duty and tax are not included; you pay them in your country on import.
My pipe is larger than DN300. How many straps do I need?
The two pipe straps in the box are 1.3 m long and fit pipes up to DN300. Each transducer is held by one strap loop around the pipe, and the loop needs about 3.14 × the pipe outside diameter, plus a little to tighten. Extra straps are the same 1.3 m straps and join onto the standard ones, so every extra pair adds 1.3 m to both loops. Work out what your pipe needs and choose the number of extra pairs in step 1 of the configurator; they are charged per pair, and the price is shown before you pay. If your pipe is DN300 or smaller and you want spares, add spare pairs of 1.3 m straps under Options in step 3.
Do I pay import duty when the meter arrives?
Yes. Import duty, VAT or GST and any customs fees are paid by you as the importer, and the rates depend on your country. UPS or your customs broker will ask for payment before or at delivery. We send the commercial invoice and packing list with the shipment and by email, and help with customs questions about the product.
When will my order arrive?
We ship from our factory within 2 weeks of payment. UPS then usually takes 3–5 working days to deliver. The configurator shows an estimated delivery date before you pay.
Which outputs can I have?
Two of five outputs are wired at the factory: 4–20 mA, pulse, RS232 / RS485 Modbus, OCT or relay. You choose the two in the configurator, at no extra cost.
Can I order 10 or more units?
Yes. For 10 units or more, email info@segmensensor.com with the part number and quantity. Our engineers recalculate the price for your quantity and reply by email.
Distributor or reseller? See what it takes to become a SEGMENsensor distributor →