RF ADMITTANCE LEVEL SENSOR

SGL-RF10 RF Admittance Level Sensor for Viscous Liquids, 50–1000 mm

SGL-RF10 is a continuous level sensor that ignores probe coating: it measures capacitance and resistance at the same time, so glue, resin or heavy oil sticking to the probe does not read as level. Range 50–1000 mm, 9–36 VDC supply, 0.5–4.5 VDC or RS485 (Modbus) output, FEP probe, G1 thread, 2.5 MPa, IP65.

50–1000 mm0.5–4.5 V / RS485IP65 · 2.5 MPaOEM volume supply
500

Product illustration (vector drawing, not a photo): display head, G1 thread, FEP probe

Key facts

SEGMENsensor SGL-RF10 is an RF admittance level sensor for continuous level measurement of viscous liquids, oils and water. It measures the capacitive and resistive components together, eliminating the error caused by probe coating, and outputs 0.5–4.5 VDC or RS485 Modbus over a 50–1000 mm range.

Last updated · SEGMENsensor Engineering Team

What is an RF admittance level sensor?

An RF admittance level sensor is a capacitive-type level sensor that solves the probe-coating problem. Admittance is the reciprocal of impedance; because inductance in a real measuring circuit is very small, admittance here effectively means capacitance and resistance. By measuring both at the same time, the sensor separates material stuck to the probe from the true liquid level. RF admittance technology typically uses an RF signal at a suitable frequency between 15 and 400 kHz.

The SGL-RF10 converts the level change into a 0.5–4.5 VDC analog signal or an RS485 Modbus output. Push buttons on the head set the range and calibrate zero and full scale (calibration by command is also possible), and the display shows the level on site. With no moving or elastic parts and a dedicated ASIC, MTBF is up to 60,000 h.

Updated 2026-11-04 · Values from the SGL-RF10 datasheet, Rev A (2026-11).

Specifications

SGL-RF10 Specifications

All values from the SGL-RF10 datasheet. Download the datasheet (PDF, 4 pages, no registration) — specifications, pin assignment, dimensions, cable codes, wiring and installation.

ParameterValue
Measurement
Application mediaViscous liquids, water, oils, liquid chemicals
Measuring range50–1000 mm
Resolution1 mm
AccuracyWater (dielectric constant ≥ 25) ±2% FS; oil (≥ 5) ±4% FS; glue (< 5) ±5% FS
Repeatability< ±1% FS
Temperature coefficient< 0.05%/°C
Electrical
Supply voltage9–36 VDC
Output signal0.5–4.5 VDC analog / RS485 (Modbus)
Load capacity≤ 20 mA
ConnectionM12 connector (5-pin)
Environment & construction
Operating temperatureIntegral version -40 to 85 °C; remote probe -55 to 200 °C
Storage temperature-40 to 100 °C
Rated working pressure2.5 MPa
Probe surface materialFEP
Process connectionG1 thread
Protection classIP65

Accuracy depends on the dielectric constant of the medium

The same sensor gives a different accuracy class on different media. A higher dielectric constant gives a stronger signal and better accuracy.

MediumDielectric constantAccuracyExample on a 1000 mm range (calculated)
Water≥ 25±2% FS±20 mm
Oil≥ 5±4% FS±40 mm
Glue< 5±5% FS±50 mm
Selection

When to Choose SGL-RF10

If your application…Then
runs above 85 °C or below -40 °Cchoose the remote (split) version — probe -55 to 200 °C
needs more than 1000 mm range, more than 2.5 MPa, or another output signaltell us in the RFQ; it is evaluated per project
needs only a high / low alarm pointsee float level switches
Features

SGL-RF10 Features and Typical Applications

Typical applications: automatic dispensing machines (glue bucket level), petrochemical storage tanks and construction vehicles (oil tank level). Suitable media: oils, heavy oil, alcohol, glue, resin, liquid chemicals, jam, syrup, dairy and other viscous liquids, and water.

Wiring

How to Wire SGL-RF10

SGL-RF10 uses an M12 5-pin connector: pin 1 (brown) is +V 9–36 VDC, pin 4 (black) is −V (GND), pin 5 (grey) is the voltage output VOUT, and pins 3 (blue) and 2 (white) are RS485 A and B.

M12 pinWire colourFunction
1Brown+V (9–36 VDC)
2WhiteRS485_B
3BlueRS485_A
4Black−V (GND)
5GreyVOUT voltage output (range settable within 0–10 VDC)

Wire colours refer to the matching SGA series cables.

12345
M12 male connector on the sensor, pin layout.
Inside the sensorRFadmittancemaincircuitVoltageoutputReverse-polarity diodeBrown (pin 1)+V (9–36 VDC)Grey (pin 5)VOUTBlack (pin 4)−V (GND)Blue (pin 3)RS485_AWhite (pin 2)RS485_BAnalog input device
Wiring diagram: connect the analog input device between VOUT and −V; the +V line has a reverse-polarity diode.
Dimensions & Installation

SGL-RF10 Dimensions and Installation

Effective range L28top dead zone562.720.3thread length5bottom dead zoneØ11Ø45Thread: G1 (55°, 11 TPI, pitch 2.309)Hex SW45M12×1 connector, 5-pin (male)
SGL-RF10 integral version, dimensions in mm. L is the effective range; overall length follows the drawing confirmed with your order.
DimensionValue (mm)
Bottom dead zone5
Top dead zone28
Thread length20.3
Probe diameterØ11
Head diameterØ45
HexSW45
ThreadG1 (55°, 11 TPI, pitch 2.309)
300°Head rotatesThread lockedLiquid
Lock the thread, then rotate the head up to 300°.
  1. Mount the sensor vertically on top of the vessel with the G1 thread (or a flange) and tighten the thread first.
  2. Rotate the head (up to 300°) so the display faces the easiest viewing direction.
  3. Check the conditions: working pressure up to 2.5 MPa; integral version -40 to 85 °C.
  4. Set the range and calibrate zero and full scale with the push buttons, or by communication command.
Ordering

How to Order SGL-RF10 and Matching Cables

Cables are accessories and are ordered separately. All are M12 5-pin, PUR jacket, Ø6 cable.

Order codeTypeCable length
SGA-M12F-02Female, open end2 m
SGA-M12F-05Female, open end5 m
SGA-M12F-10Female, open end10 m
SGA-M12FF-02Female – female2 m
SGA-M12FF-05Female – female5 m
SGA-M12FF-10Female – female10 m
SGA-M12FM-02Female – male (extension)2 m
SGA-M12FM-05Female – male (extension)5 m
SGA-M12FM-10Female – male (extension)10 m

What to include in your RFQ

ItemPlease specify / options
MediumName or dielectric constant (sets the accuracy class)
Effective range L50–1000 mm
VersionIntegral (-40 to 85 °C) or remote (probe -55 to 200 °C)
Output0.5–4.5 VDC analog or RS485 (Modbus)
Mounting and cableG1 thread or flange (flange size confirmed with the order); cable code from the table above

Ordering example: SGL-RF10, integral version, effective range L = 500 mm, RS485 (Modbus) output, G1 thread; cable SGA-M12F-05.

1–5 pcsQualification samples
5–7 working daysSample lead time
Per quotationProduction lead time and MOQ
24 h replyEvery RFQ answered by an engineer
FAQ

SGL-RF10 — Frequently Asked Questions

How is an RF admittance level sensor different from a capacitive one?
A plain capacitive sensor measures only capacitance, so material coating the probe reads as level. SGL-RF10 measures the capacitive and resistive components at the same time, which eliminates the error caused by probe coating while keeping the advantages of capacitive measurement.
What accuracy can I expect?
Accuracy depends on the dielectric constant of the medium: ±2% FS for water (dielectric constant ≥ 25), ±4% FS for oil (≥ 5) and ±5% FS for glue (< 5). Tell us the medium name or its dielectric constant when you request a quote.
What is the maximum operating temperature?
The integral version operates from -40 to 85 °C. For higher or lower temperatures choose the remote (split) version, whose probe operates from -55 to 200 °C.
How do I connect SGL-RF10 to a PLC?
Use VOUT (grey, pin 5) and −V (black, pin 4) for the 0.5–4.5 VDC analog signal, or RS485 Modbus with A on the blue wire (pin 3) and B on the white wire (pin 2). Supply 9–36 VDC on the brown wire (pin 1).
Do I need to register to download the datasheet?
No. The SGL-RF10 datasheet PDF downloads directly from this page with specifications, pin assignment, dimensions, cable ordering codes, wiring and installation. For a 3D model (STEP) or a selection review, contact our engineers.

Need SGL-RF10 for Your Project?

Send the medium, range, version and output — an engineer replies within 24 hours on working days with a quotation and the datasheet.

Request a Quote for SGL-RF10

Tell us your specification — our engineers reply within 24 hours.

OEM volume supply · samples in 5–7 days · info@segmensensor.com